Cuff leak volume as a clinical predictor for identifying post-extubation stridor.

نویسندگان

  • Warangkana Keeratichananont
  • Teeranan Limthong
  • Suriya Keeratichananont
چکیده

BACKGROUND Post-extubation stridor occurs after translaryngeal intubation results to re-intubation in a number of patients. OBJECTIVE To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor MATERIAL AND METHOD Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. Clinical stridor was observed and identified after extubation. RESULTS Among 115 patients, the cuff leak volume of less than 114 ml was used to predict post-extubation stridor with the sensitivity of 89%, specificity of 90%, positive predictive value of 65%, and negative predictive value of 98%, respectively. Among the stridor group, 12 of 19 cases (63.2%) needed re-intubation. CONCLUSION The cuff leak volume of less than 114 ml can be used as a clinical predictor for identifying post-extubation stridor

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The cuff leak test: does it "leak" any information?

Post-extubation stridor and upper-airway obstruction are multifactorial in etiology and can occur as a result of laryngotracheal edema, intubation trauma, excessive cuff pressure with mucosal ulceration, and prolonged intubation with secondary inflammation and granuloma formation.1 Cuff leak tests (CLTs) were introduced in an attempt to predict post-extubation upper-airway obstruction and reduc...

متن کامل

Intra-individual variation of the cuff-leak test as a predictor of post-extubation stridor.

BACKGROUND This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor. METHODS Prospective, clinical investigation in the ICU of a non-university hospital. CLTs were performed immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak (ΔCL...

متن کامل

Laryngeal ultrasound: a useful method in predicting post-extubation stridor. A pilot study.

The cuff-leak test was widely used for the prediction of post-extubation stridor, but controversial results limit its clinical application. The current study used real-time ultrasonography to evaluate the air-leak and hypothesised that the air-column width, measured by ultrasonography, may be correlated to the development of post-extubation stridor. From June 1, 2001 to March 1, 2002, a total o...

متن کامل

بررسی مقایسه‌ای تاثیر دگزامتازون وریدی با بودسوناید استنشاقی در کاهش استریدور بعد از اکستوباسیون در بیماران ICU

Background and Objective: Stridor is considered as a serious adverse complication of intubation that may lead to respiratory distress, reintubation, and further complications. Intravenous steroids including dexamethasone are assumed as an effective therapy. However, their associated side effects pose a limit on their usage. This study was carried out to elucidate the effect of intravenous dexam...

متن کامل

Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor

INTRODUCTION Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 95 6  شماره 

صفحات  -

تاریخ انتشار 2012