Curtailed Number Ani) Reduced Controller Movement Optimization Algorithms for Real Time Voltage/reactive Rower Control

نویسنده

  • S A Soman
چکیده

This paper addresses the problem of curtailing the number of control actions and minimizing controller movements for real-time voltagelreactive power control. Algorithms are proposed to identify the most effective subset of control actions and to minimize controller movements. An algorithmic objective function appropriate for the treatment of system security and economy is also proposed. It eliminates trial and error adjustments of weightage factors for a combined objective. A single parameter decides the priority between movement of controls and gains in security as well as loss reduction. The algorithms are compared and contrasted with SLP and SQP techniques by means of two practical systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lead-Lag Controllers Coefficients Tuning to Control Fuel Cell Based on PSO Algorithm

One of the most important Fuel cells (FCs) is Proton Exchange Membrane Fuel Cells (PEMFCs). The outputvoltage of this FC depends on current loads. This paper tries to introduce, implement and control the voltage ofPEMFC, during load variations. The output voltage of fuel cell should be constant during load variation. Toachieve this goal, a controller should be designed. Here, the Lead-Lag contr...

متن کامل

Reactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control

Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...

متن کامل

Real-Time Frequency and Voltage Control of an Islanded Mode Microgrid

In this paper, we investigated the necessity and effects of optimal control methods in the stability and performance of a micro-grid that operates in islanded mode. The micro-gird is consisted of a combine heat and power (CHP), a capacitor bank (CB), photovoltaic panel (PV) as power generation sources. In addition, battery and the building electricity and thermal load are placed on the load sid...

متن کامل

Control Stability Evaluation of Multiple Distribution Static Compensators based on Optimal Coefficients using Salp Swarm Algorithm

In order to solve the problem of voltage drop and voltage imbalance in the distribution systems, the injection of reactive power by multiple static compensators is used. The distributed generation such as photovoltaic systems could play a role of the static compensators by producing reactive power. In this paper, the integral to droop line algorithm is used to control the reactive power in busb...

متن کامل

A Local Power Control Scheme for Electronically Interfaced Distributed Generators in Islanded Microgrids

The conventional real power-frequency and reactive power-voltage droop characteristics are commonly employed to share the electric power among parallel distributed generation (DG) units. Despite some advantages such as easy implementation and no need for communication infrastructure, inaccurate reactive power sharing is one of the main disadvantages of conventional droop control. This paper pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004