A novel cell exclusion zone assay with a barrier made from room temperature vulcanizing silicone rubber
نویسندگان
چکیده
OBJECTIVE To examine the usefulness of room temperature vulcanizing (RTV) silicone rubber as a barrier material for cell exclusion zone assays. METHODS We created barriers using three types of RTV silicone rubber with differing viscosities. We then assessed the adherence of these barriers to culture dishes and their ease of removal from the dishes. We tested the effect of the newly created barriers on the extracellular matrix (ECM) protein fibronectin by attaching and then removing them from fibronectin-coated culture dishes. We also conducted cell exclusion zone assays with MIO-M1 cells using this new barrier in order to measure cell migration. We used real time reverse transcription polymerase chain reaction (RT-PCR) and immunohistochemical staining to measure the effect of fibronectin on MIO-M1 cell migration and the effect of migration (with fibronectin coating) on basic fibroblast growth factor (bFGF) expression in MIO-M1 cells. RESULTS Of the three types of RTV silicon rubber tested, KE-3495-T was the best in terms of adherence to the dish and ease of removal from the dish. When barrier attachment and removal tests were performed, this rubber type did not have an effect on the fibronectin that coated the dish. In the cell exclusion assay, removal of the barrier revealed that a cell-free area with a distinct margin had been created, which allowed us to conduct a quantitative assessment of migration. Fibronectin significantly promoted the migration of MIO-M1 cells (P = 0.02). In addition, both real time RT-PCR and immunohistological staining indicated that bFGF expression in migrating MIO-M1 cells was significantly higher than that in non-migrating cells (P = 0.03). CONCLUSIONS RTV silicone rubber can be used to create an effective barrier in cell exclusion zone assays and allows simple and low-cost multi-parametric analysis of cell migration.
منابع مشابه
Physical properties of silicone rubber.
2 Mechanical engineer, USAMBRL. 3 Major, Army Medical Specialist Corps, USAMBRL. ROOM-TEMPERATURE-VULCANIZING (RTV) silicone rubber is a versatile material and easy to handle. The ingredients from which it is formed are thick liquids that vulcanize at room temperature within a short period of time after the catalyst is added. Depending upon the relative amounts of solid and foam ingredients, th...
متن کاملRTV silicone insoles.
A cheap and fast method of providing long term accommodating insoles is described. Room temperature vulcanizing (RTV) silicone rubber is used, with suitable coverings, to provide pain relief and support for feet and ankles. The combination of physical properties of the finished item provides a useful balance between support and flexibility which results in these insoles being readily accepted b...
متن کاملMeasured limits to contamination of optical surfaces by elastomers in vacuum.
We have monitored the reflectivity of mirrors that were exposed to a fluoroelastomer (3M-Fluorel 2176) and a room-temperature vulcanizing silicone rubber (RTV-615) in vacuum. The 95% confidence limit on the decrease of mirror reflectivities was less than 0.35 ppm/week for Fluorel and <0.29 ppm/week for RTV-615.
متن کاملModified gas-permeable silicone rubber membranes for covalent immobilisation of enzymes and their use in biosensor development.
Novel enzyme membranes are introduced. Modified polymeric gas-permeable layers were developed enabling biological components which have available reactive groups (-NH2, -OH, -SH, -COOH) to couple covalently on to their surfaces. Therefore, gas-permeable two component room temperature vulcanizing (2K-RTV) silicone rubber was modified using additional cross-linking agents. Triethoxysilanes with f...
متن کاملCase Report Rehabilitation of a Patient with Auricular Defect- A Prosthodontic Approach
Introduction Loss of an auricle may be due to congenital disease, trauma, or surgical removal of benign or malignant tumors. Auricular defects can be repaired, or reconstructed with autogenous tissue, but this may be unsuitable in many situations. Additionally the use of autogenous tissues requires harvesting a graft there by adding a surgical site. A good alternative is to develop an auricular...
متن کامل