Odour intensity and hedonic tone--important parameters to describe odour annoyance to residents?

نویسندگان

  • R Both
  • K Sucker
  • G Winneke
  • E Koch
چکیده

The Guideline on Odour in Ambient Air has been in use for many years for odour regulation in Germany. The main parameter that the odour regulation authority has to take into account is the odour frequency expressed as odour hours per year. In the guideline, limit values are given for the maximum odour frequency per year. These limit values are based on field investigations in which significant relationships between odour impact and odour annoyance was found. In these investigations, odour intensity did not yield a better description of the degree of annoyance caused to the residents. The hedonic tone was not mentioned. In a new research project finished in 2003, the influence of odour intensity and hedonic tone, in addition to odour frequency, has been assessed. Two installations emitting pleasant odours, two emitting neutral and two emitting unpleasant odours, have been selected. In each case grid field measurements by a panel were carried out, and the annoyance of the residents was assessed using a special questionnaire. The results of this project are: (1) A new method to measure odour intensity and hedonic tone in the field with data record forms was developed and validated. With this method, reliable and reproducible results are obtained. (2) The parameter odour frequency based on the system of "odour hours" is suitable and sufficient to predict the odour annoyance caused by unpleasant/neutral odours. (3) In the case of pleasant odours, hedonic tone has an abundantly clear effect on the dose-response relationship between odour frequency and annoyance. Pleasant odours have a significant lower annoyance potential than unpleasant/neutral odours. (4) The odour intensity has no additional influence on this relationship. If odours are recognisable then they can cause annoyance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Odour Regulation in Germany – an improved system including odour intensity, hedonic tone and odour annoyance

For odour regulation in Germany the Guideline on Odour in ambient Air GOAA has been in use for many years. The main parameter the odour regulation authority has to take into account is the odour frequency expressed as odour hours per year. In the Guideline limit values are given for the maximum odour frequency per year. These limit values are based on investigations in the field in which signif...

متن کامل

Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose

The paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures-toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene-characterized by different odour intensity and hedonic tone. A principal com...

متن کامل

Determining tolerance to odour annoyance in communities near hog operations

La, A., Q. Zhang and Z. Gao. 2014. Determining tolerance to odour annoyance in communities near hog operations. Canadian Biosystems Engineering/Le génie des biosystèmes au Canada 56: 6.1-6.11. Quantifying the impact of odour from livestock facilities has been a challenge to researchers and environmental regulators. Physical and sensory odour attributes are commonly used to define the odour impa...

متن کامل

Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks

This paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills an...

متن کامل

Odour annoyance and physical symptoms among residents living near waste treatment centres.

Waste treatment processes produce odours and biological emissions to the environment, but their health effects are controversial. The aim of our study was to assess odour-associated self-reported physical symptoms among residents living near waste treatment centres. The study was conducted in the surroundings of five large-scale Finnish waste treatment centres with composting plants. In 2006, 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water science and technology : a journal of the International Association on Water Pollution Research

دوره 50 4  شماره 

صفحات  -

تاریخ انتشار 2004