Fast B1 field localisation in high-field MRI systems

نویسنده

  • H. Yoo
چکیده

In high-magnetic magnetic resonance imaging (MRI) systems (7 T and above), the radio frequency (RF) field shows greater inhomogeneity compared with clinical MRI systems (1.5 and 3.0 T). In multichannel RF coils, driving each coil element with convex optimisation can reduce non-uniformity of the RF field in a region of interest. In this Letter, a periodic compressed method (PCM) and a PCM after averaging are proposed in order to reduce RF coil control time at high fields. Simulation results were obtained using a human head model in 7 and 9.4 T systems, and the results are discussed in detail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical investigation of the practical range and deflection of megavoltage electron beam in the water phantom with the presence of magnetic field

Introduction: Integrated radiation therapy - MRI systems are capable of delivering high doses to the target tissues near sensitive organs and achieve better therapeutic results; however, the Applied magnetic fields for imaging, can influence the charged path, change the penetration depth and deflect the particles, laterally, leading to dose distribution variations. Therefore, i...

متن کامل

Fast phase-modulated B1+ mapping in the low flip-angle regime

Introduction and purpose: In high-field MRI phased transmit arrays are used to mitigate RF issues, e.g. optimizing the inhomogeneous B1 field using spatially tailored RF pulses played out by such an array. In order to design the RF pulses that produce the desired excitation field, the B1 field per coil must be mapped. Ideally, these B1 mapping techniques are fast and have a low SAR deposition. ...

متن کامل

Subject-loaded quadrifilar helical-antenna RF coil with high B1+ field uniformity and large FOV for 3-T MRI

A novel method for excitation of RF B1 field in high-field (3-T) magnetic resonance imaging (MRI) systems using a subject-loaded quadrifilar helical antenna as an RF coil is proposed, evaluated, and demonstrated. Design, analysis, characterization, and evaluation of the novel coil when situated in a 3-T MRI bore and loaded with different phantoms are performed and cross-validated by extensive n...

متن کامل

Safety Considerations on MRI Systems for Firefighters and Paramedics

Background and Objectives: The use of Magnetic Resonance Imaging (MRI) systems is on the rise and the number of installed systems is constantly increasing all over the world. This raises the possibility for emergency personnel to get in contact with these systems. However, the clothing and working material of paramedics and firefighters is not designed for the use on magnets. M...

متن کامل

SA2RAGE: a new sequence for fast B1+ -mapping.

At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurat...

متن کامل