EEG-based indices of anaesthesia: correlation between bispectral index and patient state index?

نویسندگان

  • G Schneider
  • A Mappes
  • T Neissendorfer
  • M Schabacker
  • H Kuppe
  • E Kochs
چکیده

BACKGROUND AND OBJECTIVE Both the bispectral and the patient state indices are derived from the electroencephalogram and have been proposed as a measure of the same clinical target, the hypnotic component of anaesthesia. The present study evaluated whether there is concordance between the bispectral and the patient state indices with regard to end-points measured simultaneously in patients undergoing surgery under general anaesthesia. METHODS Fifty-seven patients scheduled for elective abdominal, orthopaedic (Groups 1 and 2) or cardiac surgery (Group 3) under general anaesthesia were enrolled in the study. Anaesthesia was performed using remifentanil/ sevoflurane (Group 1, 19 patients), remifentanil/propofol (Group 2, 19 patients) or sufentanil/propofol/isoflurane (Group 3, 19 patients). The bispectral and the patient state indices were simultaneously recorded. Pearson's correlation between these two indices was calculated for the complete data and each group. The percentage of bispectral index values in the recommended range for general anaesthesia (45-60) that were confirmed by levels of patient state index (25-50) was calculated and vice versa. RESULTS Overall correlation between the bispectral and the patient state indices was 0.667, 0.671 in Group 1, 0.650 in Group 2 and 0.675 in Group 3 (P < 0.01). For values of the bispectral index between 45 and 60, only 40% of corresponding patient state index values were between 25 and 50. For patient state index values of 25-50, only 50% of the corresponding bispectral index values were in the range of 45-60. CONCLUSIONS Concordance between the bispectral and patient state indices is relatively weak, whereas both are thought to reflect the same clinical target, the hypnotic component of anaesthesia. As a consequence, further studies are required to compare reliability of both indices as indicators of different levels of hypnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane.

BACKGROUND Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed the changes in the raw EEG signal during surgical anaesthesia with sevoflurane. METHODS...

متن کامل

Rocuronium dose-dependently suppresses the spectral entropy response to tracheal intubation during propofol anaesthesia.

BACKGROUND The Entropy Module anaesthesia monitor displays two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE), which mainly reflects electromyography activation, is thought to indicate the adequacy of antinociception. Little is known, however, about the effects of neuromuscular blocking agents on the RE-SE. We investigated ...

متن کامل

Entropy indices vs the bispectral index for estimating nociception during sevoflurane anaesthesia.

BACKGROUND It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in est...

متن کامل

Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: a comparison with the bispectral index and the cerebral state index.

BACKGROUND The purpose of this study was to validate a new level of consciousness monitor derived from the EEG, called the index of consciousness (IoC), by comparing it with the bispectral index (BIS) and the cerebral state index (CSI) during general anaesthesia for cardiac surgery using sevoflurane, remifentanil, and atracurium. METHODS After ethical committee approval and written patient co...

متن کامل

Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofol-sufentanil anaesthesia.

BACKGROUND Manufacturers recommend maintaining anaesthesia at a bispectral index (BIS) or state entropy (SE) index value between 40 and 60. METHODS We prospectively studied 102 patients receiving propofol-sufentanil anaesthesia administered by anaesthetists blinded to these indices. The main endpoint was crude agreement (P(0)), defined as the proportion of agreement between BIS and SE index a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2004