Interhead distance measurements in myosin VI via SHRImP support a simplified hand-over-hand model.

نویسندگان

  • Hamza Balci
  • Taekjip Ha
  • H Lee Sweeney
  • Paul R Selvin
چکیده

Myosin VI walks in a hand-over-hand fashion with an average step size of 30 nm, which is much larger than its 10 nm lever arm. Recent experiments suggest that the myosin VI structure has an unfolded and flexible region in the proximal tail which makes such a large step possible. In addition, cryoelectron microscopy images of actomyosin VI show the two heads bound to the actin monomers with a broad distribution of distances, including some as close as a few nanometers. This observation, when combined with the existence of a flexible region in the structure, which takes part in stepping, challenged the hand-over-hand model. In the hand-over-hand model, the lever arm is considered to be rigid and the interhead separation should not be very different from 30 nm. We considered an alternative model in which myosin VI heads sequentially take 60 nm steps whereas the interhead separation alternates between a large and small value (x and 60 - x, where x < 30). To clarify these issues, we used a new technique, SHRImP, to measure the interhead distance of nearly rigor myosin VI molecules. Our data show a single peak at 29.3 +/- 0.7 nm, in agreement with the straightforward hand-over-hand model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The energetics of allosteric regulation of ADP release from myosin heads.

Myosin molecules are involved in a wide range of transport and contractile activities in cells. A single myosin head functions through its ATPase reaction as a force generator and as a mechanosensor, and when two or more myosin heads work together in moving along an actin filament, the interplay between these mechanisms contributes to collective myosin behaviors. For example, the interplay betw...

متن کامل

Myosin VI steps via a hand-over-hand mechanism with its lever arm undergoing fluctuations when attached to actin.

Myosin VI is a reverse direction myosin motor that, as a dimer, moves processively on actin with an average center-of-mass movement of approximately 30 nm for each step. We labeled myosin VI with a single fluorophore on either its motor domain or on the distal of two calmodulins (CaMs) located on its putative lever arm. Using a technique called FIONA (fluorescence imaging with one nanometer acc...

متن کامل

Differential labeling of myosin V heads with quantum dots allows direct visualization of hand-over-hand processivity.

The double-headed myosin V molecular motor carries intracellular cargo processively along actin tracks in a hand-over-hand manner. To test this hypothesis at the molecular level, we observed single myosin V molecules that were differentially labeled with quantum dots having different emission spectra so that the position of each head could be identified with approximately 6-nm resolution in a t...

متن کامل

Myosin V walks hand-over-hand: single fluorophore imaging with 1.5-nm localization.

Myosin V is a dimeric molecular motor that moves processively on actin, with the center of mass moving approximately 37 nanometers for each adenosine triphosphate hydrolyzed. We have labeled myosin V with a single fluorophore at different positions in the light-chain domain and measured the step size with a standard deviation of <1.5 nanometers, with 0.5-second temporal resolution, and observat...

متن کامل

Switch between Large Hand-Over-Hand and Small Inchworm-like Steps in Myosin VI

Many biological motor molecules move within cells using stepsizes predictable from their structures. Myosin VI, however, has much larger and more broadly distributed stepsizes than those predicted from its short lever arms. We explain the discrepancy by monitoring Qdots and gold nanoparticles attached to the myosin-VI motor domains using high-sensitivity nanoimaging. The large stepsizes were at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 89 1  شماره 

صفحات  -

تاریخ انتشار 2005