Automatic control of finite element models for temperature-controlled radiofrequency ablation

نویسندگان

  • Dieter Haemmerich
  • John G Webster
چکیده

BACKGROUND The finite element method (FEM) has been used to simulate cardiac and hepatic radiofrequency (RF) ablation. The FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. In both hepatic and cardiac RF ablation a common control mode is temperature-controlled mode. Commercial FEM packages don't support automating temperature control. Most researchers manually control the applied power by trial and error to keep the tip temperature of the electrodes constant. METHODS We implemented a PI controller in a control program written in C++. The program checks the tip temperature after each step and controls the applied voltage to keep temperature constant. We created a closed loop system consisting of a FEM model and the software controlling the applied voltage. The control parameters for the controller were optimized using a closed loop system simulation. RESULTS We present results of a temperature controlled 3-D FEM model of a RITA model 30 electrode. The control software effectively controlled applied voltage in the FEM model to obtain, and keep electrodes at target temperature of 100 degrees C. The closed loop system simulation output closely correlated with the FEM model, and allowed us to optimize control parameters. DISCUSSION The closed loop control of the FEM model allowed us to implement temperature controlled RF ablation with minimal user input.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Hepatic Radiofrequency Ablation Probes using Temperature-Dependent Electrical Conductivity

BACKGROUND Few finite element models (FEM) have been developed to describe the electric field, specific absorption rate (SAR), and the temperature distribution surrounding hepatic radiofrequency ablation probes. To date, a coupled finite element model that accounts for the temperature-dependent electrical conductivity changes has not been developed for ablation type devices. While it is widely ...

متن کامل

Comparing the Efficacy of Temperature-Controlled Radiofrequency Tonsil Ablation versus CO2-Laser Cryptolysis in the Treatment of Halitosis

Introduction: Halitosis and foreign body sensation are two common and disturbing symptoms of chronic caseous tonsillitis (CCT). The aim of this study was to compare the efficacy and safety of temperature-controlled radiofrequency (TC-RF) tonsil ablation with CO2-laser cryptolysis (CO2-LC) in the treatment of patients with halitosis caused by CCT.   Materials and Methods: Sixty-two patients who ...

متن کامل

بررسی اثر رادیوفرکوئنسی لوزه ها در درمان بوی بد دهان ناشی از التهاب مزمن لوزه همراه با کازئوم

Introduction & Objective: Chronic tonsillitis with caseum has been proven to be the cause of halitosis. The objective of this study was to evaluate the efficacy and safety of temperature-controlled radiofrequency tonsil ablation in the treatment of halitosis caused by chronic tonsil-litis with caseum. Materials & Methods: In this clinical trial study 28 adult patients with halitosis due to ch...

متن کامل

Thermal modeling of lesion growth with radiofrequency ablation devices

BACKGROUND Temperature is a frequently used parameter to describe the predicted size of lesions computed by computational models. In many cases, however, temperature correlates poorly with lesion size. Although many studies have been conducted to characterize the relationship between time-temperature exposure of tissue heating to cell damage, to date these relationships have not been employed i...

متن کامل

FEM analysis of RF breast ablation: multiprobe versus cool-tip electrode.

BACKGROUND Radio-frequency ablation (RFA) has recently received much attention as an effective minimally invasive strategy for the local treatment of tumors. The purpose of this study was to evaluate the efficacy of single-needle cool-tip RF breast ablation in terms of temperature distribution and duration of the procedure as compared to multiprobe RF breast ablation. MATERIALS AND METHODS Tw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2005