Defining biomechanical endpoints for tissue engineered heart valve leaflets from native leaflet properties

نویسندگان

  • W. David Merryman
  • George C. Engelmayr
  • Jun Liao
  • Michael S. Sacks
چکیده

The design and development of functional engineered tissues is dependent on multiple considerations, with biomechanics paramount for load-bearing constructs such as tissue engineered heart valves. As the cryopreserved allograft is the current standard for valve replacement in pediatric patients, identifying and quantifying essential structural–mechanical properties of the native valve leaflet is a crucial step in the engineered valve leaflet design process. Native valve leaflet properties provide an intuitive basis for assessing engineered valvular tissue performance, and can potentially be used as biomechanical endpoints for qualifying engineered leaflets prior to clinical applications. In this short review, we present three analysis techniques that have been used by our lab and others for characterizing heart valve leaflet biomechanical response and discuss the relevance of these properties as candidate endpoints for engineered leaflet tissues. The studies presented herein focused primarily on the aortic valve, which most frequently warrants repair or replacement in the general population and has been useful in our understanding of bioprosthetic heart valve mechanics. However, these analysis techniques are directly applicable for pulmonary and most engineered valve leaflets. Where data is available, initial studies applying these techniques for in vitro assessment of scaffolds and engineered valve leaflets are presented. The development of a tissue engineered heart valve for the pediatric population is conceptually appealing, since few options currently exist due to the lack of growth potential in non-viable prosthetics and size limitations. While significant challenges remain, we believe that a derivative of the current tissue engineered heart valve paradigm will ultimately yield a design suitable for clinical evaluation. The role of biomechanics in this process will be to identify and quantify the structural–mechanical endpoints essential for appropriate heart valve leaflet function, while guiding investigators prior to and during clinical evaluation. D 2005 Elsevier Ireland Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decellularized tissue-engineered heart valve leaflets with recellularization potential.

Tissue-engineered heart valves (TEHV) have been proposed as a promising solution for the clinical needs of pediatric patients. In vivo studies have shown TEHV leaflet contraction and regurgitation after several months of implantation. This has been attributed to contractile cells utilized to produce the extracellular matrix (ECM) during TEHV culture. Here, we utilized such cells to develop a ma...

متن کامل

Tri-layered elastomeric scaffolds for engineering heart valve leaflets.

Tissue engineered heart valves (TEHVs) that can grow and remodel have the potential to serve as permanent replacements of the current non-viable prosthetic valves particularly for pediatric patients. A major challenge in designing functional TEHVs is to mimic both structural and anisotropic mechanical characteristics of the native valve leaflets. To establish a more biomimetic model of TEHV, we...

متن کامل

Tissue-engineered mitral valve: morphology and biomechanics †.

OBJECTIVES The present study aimed at developing tissue-engineered mitral valves based on cell-free ovine mitral allografts. METHODS The ovine mitral valves (OMVs) (n = 46) were harvested in the local slaughter house. They were decellularized using detergent solutions and DNase. The effectiveness of decellularization was assessed by histological (haematoxylin-eosin, Movat's pentachrome) and i...

متن کامل

Planar biaxial behavior of fibrin-based tissue-engineered heart valve leaflets.

To design more effective tissue-engineered heart valve replacements, the replacement tissue may need to mimic the biaxial stress-strain behavior of native heart valve tissue. This study characterized the planar biaxial properties of tissue-engineered valve leaflets and native aortic valve leaflets. Fibrin-based valve equivalent (VE) and porcine aortic valve (PAV) leaflets were subjected to incr...

متن کامل

Biomechanical properties of native and tissue engineered heart valve constructs.

Due to the increasing number of heart valve diseases, there is an urgent clinical need for off-the-shelf tissue engineered heart valves. While significant progress has been made toward improving the design and performance of both mechanical and tissue engineered heart valves (TEHVs), a human implantable, functional, and viable TEHV has remained elusive. In animal studies so far, the implanted T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006