Haemolysis as a first sign of thromboembolic event and acute pump thrombosis in patients with the continuous-flow left ventricular assist device HeartMate II

نویسندگان

  • S. Akin
  • O.I. Soliman
  • A.A. Constantinescu
  • F. Akca
  • O. Birim
  • R.T. van Domburg
  • O. Manintveld
  • K. Caliskan
چکیده

BACKGROUND Despite advances in pump technology, thromboembolic events/acute pump thrombosis remain potentially life-threatening complications in patients with continuous-flow left ventricular assist devices (CF-LVAD). We sought to determine early signs of thromboembolic event/pump thrombosis in patients with CF-LVAD, which could lead to earlier intervention. METHODS We analysed all HeartMate II recipients (n = 40) in our centre between December 2006 and July 2013. Thromboembolic event/pump thrombosis was defined as a transient ischaemic attack (TIA), ischaemic cerebrovascular accident (CVA), or pump thrombosis. RESULTS During median LVAD support of 336 days [IQR: 182-808], 8 (20 %) patients developed a thromboembolic event/pump thrombosis (six TIA/CVA, two pump thromboses). At the time of the thromboembolic event/pump thrombosis, significantly higher pump power was seen compared with the no-thrombosis group (8.2 ± 3.0 vs. 6.4 ± 1.4 W, p = 0.02), as well as a trend towards a lower pulse index (4.1 ± 1.5 vs. 5.0 ± 1.0, p = 0.05) and a trend towards higher pump flow (5.7 ± 1.0 vs. 4.9 ± 1.9 L m, p = 0.06). The thrombosis group had a more than fourfold higher lactate dehydrogenase (LDH) median 1548 [IQR: 754-2379] vs. 363 [IQR: 325-443] U/L, p = 0.0001). Bacterial (n = 4) or viral (n = 1) infection was present in 5 out of 8 patients. LDH > 735 U/L predicted thromboembolic events/pump thrombosis with a positive predictive value of 88 %. CONCLUSIONS In patients with a CF-LVAD (HeartMate II), thromboembolic events and/or pump thrombosis are associated with symptoms and signs of acute haemolysis as manifested by a high LDH, elevated pump power and decreased pulse index, especially in the context of an infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.

OBJECTIVES The aim of this study was to determine whether differences in continuous flow left ventricular assist devices (LVADs) may lead to differences in the von Willebrand profile and the occurrence of bleeding and thromboembolic events. BACKGROUND The HeartMate II (Thoratec Corp., Pleasanton, California) and HeartWare Ventricular Assist Device (HVAD) (HeartWare, Inc., Framingham, Massachu...

متن کامل

Editorial comment: Adverse events in long-term ventricular assist device therapy.

the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2016