Effect of window reflections on photonic Doppler velocimetry measurements.

نویسندگان

  • T Ao
  • D H Dolan
چکیده

Photonic Doppler velocimetry (PDV) has rapidly become a standard diagnostic for measuring velocities in dynamic compression research. While free surface velocity measurements are fairly straightforward, complications occur when PDV is used to measure a dynamically loaded sample through a window. Fresnel reflections can severely affect the velocity and time resolution of PDV measurements, especially for low-velocity transients. Shock experiments of quartz compressed between two sapphire plates demonstrate how optical window reflections cause ringing in the extracted PDV velocity profile. Velocity ringing is significantly reduced by using either a wedge window or an antireflective coating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision in photonic Doppler velocimetry.

While photonic Doppler velocimetry (PDV) is becoming a common diagnostic in dynamic compression research, its limiting accuracy and precision are not well understood. Velocity resolution is known to be inversely proportional to the time resolution, but resolution estimates differ by one to two orders of magnitude. Furthermore, resolution varies with the number of recorded signals and how these ...

متن کامل

Are Uterine and Ovarian Artery Doppler Velocimetry Values Good Pregnancy Predictors in Clomiphene Citrate Cycles?

Background We conducted this prospective study to evaluate the prognostic significance of uterine and ovarian artery Doppler velocimetry in clomiphene citrate (CC) cycles. MaterialsAndMethods A total of 80 patients with unexplained infertility were given 100 mg/day of CC from day 3 to day 7 of their cycles in this current prospective study. On cycle day 3, before administration of CC, each pati...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

The Relationship of Uterine Artery Doppler Velocimetry Findings and Hemoglobin Concentration with Pregnancy Outcomes in Pre-eclampsia

Abstract Background: Epidemiologic studies have shown the relationship of maternal hemoglobin level and abnormal findings in uterine Doppler sonography with pregnancy- related complications. In this study, we evaluated the relationship of uterine artery Doppler velocimetry findings and hemoglobin level with the outcomes of pregnancy in women with preeclampsi...

متن کامل

Advanced Algorithms for Microscale Particle Image Velocimetry

The recent explosive increase in the use of  uidic microelectromechanical systems (MEMS) has subsequently driven the development of  uidic measurement techniques capable of measuring velocities at length scales small enough to be of use in characterizing and optimizing these new devices. Recently, several techniques have demonstrated spatial resolutions smaller than 1001mbut larger than 101m....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 2011