Use of potassium concentrations as a quality-of-service metric for phlebotomists detects systematic preanalytical biases and facilitates their correction.

نویسندگان

  • Matthew B Greenblatt
  • Matthew Torre
  • Janet Means
  • Milenko Tanasijevic
  • Lillian Vitale Pedulla
  • Craig A Bunnell
  • Michael J Conrad
  • Petr Jarolim
چکیده

The detection and monitoring of preanalytical bias in the clinical laboratory can be challenging, as bias can be introduced at any point from specimen collection to sample processing, and those biases stemming from sample collection or handling before delivery to the laboratory can be difficult to measure and eliminate. In particular, variations in potassium concentrations due to preanalytical sources of error are a pervasive and clinically significant problem (1–3 ). Initial concern regarding spuriously increased potassium concentrations ( 5.2 mmol/L) occurring in the laboratory of the Dana Farber Cancer Institute was raised by clinicians reporting patients displaying increased potassium without any apparent clinical justification. Review of the medical records of the patients involved demonstrated that the majority had potassium values within the reference interval on the draw before the increased value, with a mean increase in potassium of 1.2 (0.7) mmol/L vs the prior value. Retesting on an alternative platform confirmed hyperkalemia. To assess for a preanalytical cause of these values, samples were redrawn on the same day from a series of patients with potassium values 5.2 mmol/L. This assessment demonstrated that in 27 of 28 patients tested, potassium was in the reference interval upon retesting with an independent sample. The mean degree of decrease in potassium upon redraw was 0.9 (0.7) mmol/L. The maximum decrease observed was 2.2 mmol/L. Altogether, these findings strongly suggested that a preanalytical source of error was responsible for the increases in potassium. After excluding hemolysis, potassium release from leukocytes, or cell lysis during centrifugation as contributing factors, we considered whether the phenomenon of spuriously increased potassium values might relate to the draw technique used by specific phlebotomists. Analysis of mean potassium values by specific phlebotomists demonstrated a significant effect (P 0.0001 by 1-way ANOVA) of the phlebotomist performing the draw (data not shown). As an example, a histogram of the potassium values from each draw from 2 phlebotomists displaying higher average potassium values was plotted relative to the potassium values across the institution (Figure 1). Demonstration that specific phlebotomists were strongly associated with increased rates of hyperkalemia prompted a systematic evaluation of phlebotomy practices at the institution. In particular, it was noted that several phlebotomists were either using squeeze balls or encouraging fist clenching during draws, despite these maneuvers being prohibited by institutional policy. Additionally, occasionally excessive vein tapping before draw and variations from the policy of using 20-gauge needles to minimize hemolysis were observed. In response to this, a period of direct observation and phlebotomist retraining was instituted in November through December 2013, emphasizing correction of the deviations from institutional protocol noted above. The observation that selected phlebotomists consistently displayed increased potassium values in their draws suggested that the degree of deviation in average potassium values could function as a quality-of-service metric reported back to each phlebotomist. After the period of retraining, phlebotomy staff had monthly meetings with supervisors where data regarding the mean potassium values and number of potassium values 5.2 mmol/L from their draws during the prior month were reviewed. Continued monitoring demonstrated that this program was successful in substantially lowering the incidence of pseudohyperkalemia across the institution. Without any alterations to the potassium assay itself, the percentage of potassium values 5.2 mmol/L reported each month fell by approximately 39% relative to the start of the study. For a subset of 5 phlebotFig. 1. The distribution of potassium values for 2 phlebotomists associated with significantly increased potassium values are displayed versus the institutional distribution. Clinical Chemistry 60:11 000 – 000 (2014) Letters to the Editor

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Potassium Concentrations as a Quality-of-Service Metric for Phlebotomists Detects Systematic Preanalytical Biases and Facilitates Their Correction

1. Spencer CA, Takeuchi M, Kazarosyan M, Wang CC, Guttler RB, Singer PA, et al. Serum thyroglobulin autoantibodies: prevalence, influence on serum thyroglobulin measurement, and prognostic significance in patients with differentiated thyroid carcinoma. J Clin Endocrinol Metab 1998;83:1121–7. 2. Kushnir MM, Rockwood AL, Roberts WL, Abraham D, Hoofnagle AN, Meikle AW. Measurement of thyroglobulin...

متن کامل

Required Structures for Family Physician Program to Achieving Service Quality Dimensions in Primary Health Care: a systematic review

Background and Aim: In recent years, the family physician plan has been implemented as a main strategy of health system in Iran. Therefore, the necessity to reform organizational structure based on experiences of other countries is felt more than before. The aim of this study was to explore required structures of Family Physician Program to achieve service quality dimensions in Primary Health c...

متن کامل

Preanalytical conditions of point-of-care testing in the intensive care unit are decisive for analysis reliability

BACKGROUND Point-of-care testing (POCT) systems enable a wide range of tests to be rapidly performed at the bedside and have attracted increasing interest in the intensive care unit (ICU). However, previous studies comparing the concordance of POCT with central laboratory testing have reported divergent findings. Most reported studies on POCT reliability have focused on analyzer performance rat...

متن کامل

Improving Success Ratio in Multi-Constraint Quality of Service Routing

Multi-constraint quality-of-service routing will become increasingly important as the Internet evolves to support real-time services. It is well known however, that optimum multi-constraint QoS routing is computationally complex, and for this reason various heuristics have been proposed for routing in practical situations. Among these methods, those that use a single mixed metric are the mo...

متن کامل

Required Structures for Family Physician Program for Achieving Service Quality Dimensions in Primary Health Care: a Systematic Review

Background: The Structure of Health System affects quality of care in family physician program. This study aimed to explore the required structures of Family Physician Program for achieving service quality dimensions in Primary Health care through analyzing country experiences. These structures will be useful in achievement of quality health care in family physician system. Methods: In this sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 60 11  شماره 

صفحات  -

تاریخ انتشار 2014