Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
نویسنده
چکیده
The effects of drift on calibrations carried out by comparison have been studied at the National Institute of Standards and Technology for many years, and a number of strategies have been introduced to combat these effects. One strategy, the use of comparison designs which are inherently immune to linear drift, was developed specifically for mass comparison measurements. These techniques, developed for simultaneous comparisons, are extended to the case of non-simultaneous comparisons, such as gage block calibrations, where each artifact is measured separately, and the comparison is made mathematically from the individual measurements.
منابع مشابه
Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran
Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...
متن کاملComputer vision assisted virtual reality calibration
A computer vision assisted semi-automatic virtual reality (VR) calibration technology has been developed that can accurately match a virtual environment of graphically simulated three-dimensional (3-D) models to the video images of the real task environment. In conventional model-based computer vision, camera calibration and object localization are performed sequentially. This sequential update...
متن کاملMINIMUM WEIGHT AND DRIFT DESIGN OF STEEL MOMENT FRAMES SUBJECTED TO BLAST
Design of blast resistant structures is an important subject in structural engineering, attracting the attention of governments, researchers, and engineers. Thus, given the benefits of optimization in engineering, development and assessment of optimization methods for optimum design of structures against blast is of great importance. In this research, multi-objective optimization of steel momen...
متن کاملThe next generation of low-cost personal air quality sensors for quantitative exposure monitoring
Advances in embedded systems and low-cost gas sensors are enabling a new wave of low-cost air quality monitoring tools. Our team has been engaged in the development of low-cost, wearable, air quality monitors (M-Pods) using the Arduino platform. These M-Pods house two types of sensors – commercially available metal oxide semiconductor (MOx) sensors used to measure CO, O3, NO2, and total VOCs, a...
متن کاملLong-Term Stability of One-Inch Condenser Microphones Calibrated at the National Institute of Standards and Technology
The devices calibrated most frequently by the acoustical measurement services at the National Institute of Standards and Technology (NIST) over the 50-year period from 1963 to 2012 were one-inch condenser microphones of three specific standard types: LS1Pn, LS1Po, and WS1P. Due to its long history of providing calibrations of such microphones to customers, NIST is in a unique position to analyz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 98 شماره
صفحات -
تاریخ انتشار 1993