Fascicular Visual Field Defects in Open-Angle Glaucoma: Evaluation with Microperimetry
نویسندگان
چکیده
Purpose. Use of microperimetry (Mp-1), correlating with Humphrey perimetry (30-2 program), in patients affected by primary open-angle glaucoma (POAG) with perimetric defects, in order to obtain an evaluation of the accuracy of the results obtained by Mp-1. Materials and Methods. In this study 40 eyes of 25 patients affected by POAG with perimetric defects were included. All patients underwent microperimetry test by Nidek Mp-1 (NAVIS software version 1.7.2, Nidek Technologies). Mean sensitivity values expressed in decibel (dB) of all tested dots and mean values for each quadrant obtained by microperimetric test were correlated with corresponding quadrants obtained by static perimetry analysis. Data were analyzed by Pearson's correlation and Bland-Altman analysis. Results. Interpolated data showed that mean sensitivity values in all spots tested by Mp-1 (11.98 dB, SD 4.31) may be significantly correlated with mean total values obtained by Humphrey 30-2 perimetry (17.95, SD 4.32), with correlation coefficient of 0.556. Conclusions. Topographic visualization of the perimetric alteration by microperimetry allows retesting areas with reduced sensitivity which are topographically visualized and displayable on the ocular fundus examination, avoiding worsening of the functional defect by better modulation of the antiglaucoma therapy and therefore it allows better monitoring of the pathologic functional damage.
منابع مشابه
Pearls for Correct Assessment of Optic Disc at Glaucoma Diagnosis
T he correct evaluation of the optic disc, and related structures in ophthalmoscopy, is critical for the diagnosis of open angle glaucoma because usually glaucomatous optic nerve damage firstly occurs in the optic disc before detectable visual field defects become apparent; however, some studies have demonstrated that visual field defects can also be found without any glaucomatous changes in th...
متن کاملSignificance of Visual Evoked Potentials in the Assessment of Visual Field Defects in Primary Open-Angle Glaucoma: A Review
Visual evoked potentials is an important visual electrophysiological tool which has been used for the evaluation of visual field defects in primary open-angle glaucoma and is an appropriate objective measure of optic nerve function. Significant correlations between the magnitude of the VEP parameters and MD of Humphrey static perimetry suggest that the impaired visual cortical responses observe...
متن کاملA comparative study of visual field defects seen in patients with low-tension glaucoma and chronic simple glaucoma.
In a study comparing the visual field defects of patients with chronic simple and low-tension glaucoma differences in the nature of the defect were found between the 2 groups. Patients with low-tension glaucoma had far 'steeper sided' defects than those seen in chronic simple glaucoma (p less than 0.01).
متن کاملEvaluation of Contrast Sensitivity, Chromatic Vision, and Reading Ability in Patients with Primary Open Angle Glaucoma
Purpose. To compare contrast sensitivity, acquired color vision deficiency, and reading ability in patients with glaucoma at different stages of the disease and to establish correlations between visual field parameters and visual function scores. Methods. This prospective cross-sectional study included 121 glaucoma patients. Subjects with a diagnosis of chronic open angle glaucoma were recruite...
متن کاملCorrelation between peripapillary retinal nerve fiber layer thickness and fundus autofluorescence in primary open-angle glaucoma
PURPOSE To investigate the relationship between retinal nerve fiber layer (RNFL) thickness and retinal pigment epithelium alterations in patients with advanced glaucomatous visual field defects. METHODS A consecutive, prospective series of 82 study eyes with primary open-angle glaucoma and advanced glaucomatous visual field defects were included in this study. All study participants underwent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016