Analytical Assessment for Comparisons of Triple-T Precast- Concrete-Timber Composite Floor using Gamma method
نویسندگان
چکیده
Concrete-timber composite floor is a construction technique combining two materials, concrete and timber, connected together using some form of interlayer shear connectors either positioned discretely or continuously along the span of the floor. The interlayer connections provide the desired composite action, where the degree of this composite action is governed by the types of connection system used in the concretetimber composite system. This analytical method. The analytical method here refers to a design procedure known as Gamma Method recommended in the Eurocode 5 Annex B for bending stiffness, (EI)eff. This quantity obtained experimentally and analytically was compared and the reliability of Gamma method was
منابع مشابه
Assessment of Timber Floor Vibration Performance: a Case Study in Italy
Vibrations induced by people walking is one of the most important issue in timber floor design. Low natural frequency and low mass require a careful analysis in order to prevent significant annoyance and to guarantee an acceptable human comfort. This paper is concerned with the assessment of vibration performance of a timber-concrete composite timber floor and a cross laminated timber floor use...
متن کاملDesigning a prefabricated sandwich composite roofing system Made up of resisting facings and light-weight concrete core with truss-shaped connectors
In this paper, a new roofing system is introduced, which is constructued using the precast composite sandwich panels. This roofing sandwich panels system consists of three kinds of precast concrete sandwich panels including capital panels, beam or between columns panels, and slab or middle panels. The panels are composed of three layers; A high strength reinforced concrete top layer. A thick la...
متن کاملFEM models of composite timber-lightweight concrete floor systems
Paper presents the main principals in designing wood-lightweight concrete composite floor structures using FEM models. All design-related analyses are performed by means of the FEA COSMOS/M program. Paper emphasises some important details in FEM model design (how to choose appropriate finite elements for different types of materials, how to connect concrete slab and timber beams to work togethe...
متن کاملStructural Tests of Concrete Composite - Cross - Laminated Timber Floors Final Report
Experimental tests of a composite concrete-cross-laminated timber (CLT) floor system were conducted. The floor system was constructed with 5-ply CLT panels (6.75 in. thick) made composite with a 2.25 in. thick reinforced concrete topping slab. Four series of tests were performed using different specimen configurations and laboratory testing methods. Tests included: (1) Comparative one-way bendi...
متن کاملPrecast Piles for Route 40 Bridge in Virginia Using Concrete Filled FRP Tubes
and findings of laboratory and field tests of a new generation of precast composite piles used for the first time in the construction of the Route 40 highway bridge over the Nottoway River in Virginia. The piles consisted of 24.6 in. (625 mm) diameter concrete-filled glass fiber reinforced polymer (GFRP) circular tubes, with a 0.21 in. (5.3 mm) wall thickness. The composite piles extended above...
متن کامل