Repeatability and reproducibility of product ion abundances in electron capture dissociation mass spectrometry of peptides.
نویسندگان
چکیده
Site-specific reproducibility and repeatability of electron capture dissociation (ECD) in Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) are of fundamental importance for product ion abundance (PIA)-based peptide and protein structure analysis. However, despite the growing interest in ECD PIA-based applications, these parameters have not yet been investigated in a consistent manner. Here, we first provide a detailed description of the experimental parameters for ECD-based tandem mass spectrometry performed on a hybrid linear ion trap (LTQ) FT-ICR MS. In the following, we describe the evaluation and comparison of ECD and infrared multiphoton dissociation (IRMPD) PIA methodologies upon variation of a number of experimental parameters, for example, cathode potential (electron energy), laser power, electron and photon irradiation periods and pre- irradiation delays, as well as precursor ion number. Ranges of experimental parameters that yielded an average PIA variation below 5% and 15% were determined for ECD and IRMPD, respectively. We report cleavage site-dependent ECD PIA variation below 20% and correlation coefficients between fragmentation patterns superior to 0.95 for experiments performed on three FT-ICR MS instruments. Overall, the encouraging results obtained for ECD PIA reproducibility and repeatability support the use of ECD PIA as a complementary source of information to m/z data in radical-induced dissociation applied for peptide and protein structure analysis.
منابع مشابه
Distinguishing and quantifying peptides and proteins containing D-amino acids by tandem mass spectrometry.
Tandem mass spectrometry (MS/MS) utilizing both electron capture dissociation (ECD) and collisionally activated dissociation (CAD) was used to develop a qualitative and quantitative analytical method for chiral analysis of individual amino acid residues in polypeptides. ECD produced a more distinct chiral recognition than CAD, which is attributed to the smaller degree of vibrational excitation ...
متن کاملNegative-ion electron capture dissociation: radical-driven fragmentation of charge-increased gaseous peptide anions.
The generation of gaseous polyanions with a Coulomb barrier has attracted attention as exemplified by previous studies of fullerene dianions. However, this phenomenon has not been reported for biological anions. By contrast, electron attachment to multiply charged peptide and protein cations has seen a surge of interest due to the high utility for tandem mass spectrometry (MS/MS). Electron capt...
متن کاملPeptide and protein characterization by high-rate electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry.
The analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-inject...
متن کاملElectron capture dissociation of singly and multiply phosphorylated peptides.
Analysis of phosphotyrosine and phosphoserine containing peptides by nano-electrospray Fourier transform ion cyclotron resonance (FTICR) mass spectrometry established electron capture dissociation (ECD) as a viable method for phosphopeptide sequencing. In general, ECD spectra of synthetic and native phosphopeptides appeared less complex than conventional collision activated dissociation (CAD) m...
متن کاملAnalysis of the trypanosome flagellar proteome using a combined electron transfer/collisionally activated dissociation strategy.
The use of electron-transfer dissociation as an alternative peptide ion activation method for generation of protein sequence information is examined here in comparison with the conventional method of choice, collisionally activated dissociation, using a linear ion trapping instrument. Direct comparability between collisionally and electron-transfer-activated product ion data were ensured by emp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of mass spectrometry
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2011