Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

نویسندگان

  • Jia Hu
  • Hong Qian
  • Ya-jiao Li
  • Jun Gu
  • Jing Janice Zhao
  • Er-yong Zhang
چکیده

BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. METHODS One-hundred and six patients with and without moderate prosthesis-patient mismatch early after implantation of a 17-mm Regent valve at aortic position were included. Both clinical and echocardiographic assessments were performed preoperatively, at discharge and during follow-up period (mean follow-up time 52.6 ± 11.9 months). RESULTS The prevalence of moderate prosthesis-patient mismatch was documented in 46 patients (43.4%) at discharge. During the follow-up period, no difference in the regression of left ventricular mass, decrease of transvalvular pressure gradients, mortality and prosthesis-related complications was observed between patients with and without moderate prosthesis-patient mismatch. After adjustment for several risk factors, moderate prosthesis-patient mismatch was associated with increased midterm mortality in patients with baseline left ventricular ejection fraction<50% (HR: 1.80, p=0.02), but with normal prognosis in those with preserved LV function. Younger age (cut off value=65 years) was not an independent predictor of increased midterm mortality and valve-related complications in patients with moderate prosthesis-patient mismatch. CONCLUSIONS Moderate prosthesis-patient mismatch after aortic valve replacement with a small mechanical prosthesis is associated with increased mortality and adverse events in patients with pre-existing left ventricular dysfunction. Selected patients with small aortic annulus can experience satisfactory clinical improvements and midterm survival after aortic valve replacement with a 17-mm Regent valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case of aortic valve replacement with St. Jude Medical Regent valve (first implant in Japan).

The St. Jude Medical (SJM) Regent valve was developed as a new mechanical valve by improving the conventional SJM valve. The effective orifice area is wider than that of Hemodynamic Plus (HP) series. The efficacy of the new valve has been reported in Europe and the United States. On October 26, 2004, we first performed aortic valve replacement (AVR) with the SJM Regent valve for aortic valve st...

متن کامل

Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position.

BACKGROUND The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. METHODS AND RESULTS Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62+/-13 years; 69% were fem...

متن کامل

Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up

BACKGROUND Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). METHODS From January 2008 to Ap...

متن کامل

Vertical split of the posterior leaflet increases mitral valve area.

I read with interest the article by Kurazumi and colleagues about mitral valve replacement for a severely calcified annulus [1]. I congratulate the authors for their excellent results and simple technique to overcome this difficult problem. My only concern is about the valve size of 21 mm in the mitral position producing about 2 cm mitral valve area. This might be marginal for small-body-weight...

متن کامل

Enlargement of mitral valve ring in a young woman with severe prosthesis-patient mismatch.

Mechanical prosthesis is the first choice for valve replacement at the mitral position in children. Replacement of the original prosthesis because of prosthesis-patient mismatch (PPM) is almost inevitable when prostheses are implanted in small children. The impact of PPM on long-term mortality becomes significant when the effective orifice area (EOA) is severely reduced. In these cases prosthes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014