Relative humidity in incubators.

نویسندگان

  • E Bardell
  • J Freeman
  • E N Hey
چکیده

In a previous paper Hey and Maurice (1968) have reported the effect of changes of relative humidity on the heat production and heat loss in normal naked babies in a specially constructed metabolic chamber under controlled environmental conditions. In order to evaluate the clinical relevance of these observations we have studied the control of relative humidity that could be achieved in three commercial incubators. A means of assessing the operative environmental temperature in such incubators has already been published (Hey and Mount, 1967). The amount of water that can be contained as vapour in air depends on the temperature of the air (Fig. 1 heavy line, 100% relative humidity). By definition the absolute humidity is the amount of water present as vapour in a given weight or volume of air, and the relative humidity (RH) is the amount of water vapour actually present, expressed as a percentage of the maximum amount that could be present at that temperature. The air in hospital wards is usually about 50% RH (Fig. 1 point A); if this air is warmed from about 20 to 300 C. without the addition of extra water vapour, its absolute humidity will remain constant but its relative humidity will fall to 25% (Fig. 1 point B). For this reason warm-air incubators contain humidifying devices. Air can contain more water than indicated by the heavy 100% RH line in Fig. 1 at any given temperature only as liquid droplets, and these droplets of mist will only remain in suspension for a limited time, depending on their size. Avery, Galina, and Nachman (1967) have recently reviewed the use of mist therapy in paediatrics. This specialized aspect of humidity control was not covered in the present study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survivability of the Subterranean Termite Heterotermes aureus (Snyder) (Isoptera: Rhinotermitidae) When Exposure to Different Temperatures and Relative Humidity

Survivability of Heterotermes aureus (Snyder) was tested under varying temperature and relative humidity regimes in laboratory incubators over seven day periods. Initial tests showed that RH had a strong influence on H. aureus survival. Survival was significantly higher (P<.05) at 90% RH than 50% RH when held at a constant temperature of 29.4 o C. Four temperatures were tested at a constant RH ...

متن کامل

Humidification of incubators.

The effect of increasing the humidity in incubators was examined in 62 infants of less than 30 weeks' gestation. Thirty three infants nursed in high humidity for two weeks were compared retrospectively with 29 infants from an earlier study who were nursed under plastic bubble blankets or with topical paraffin but without raised humidity. Humidification reduced skin water loss and improved maint...

متن کامل

Web-based remote monitoring of infant incubators in the ICU

A web-based real-time operating, management, and monitoring system for checking temperature and humidity within infant incubators using the Intranet has been developed and installed in the infant Intensive Care Unit (ICU). We have created a pilot system which has a temperature and humidity sensor and a measuring module in each incubator, which is connected to a web-server board via an RS485 por...

متن کامل

Effect of humidity on production and loss of heat in the newborn baby.

In 1955 Clement Smith wrote: 'Most of us who work in neonatal pediatrics are distressingly familiar with the sight of a small infant surrounded by a fog of vapour within a closed tent or incubator. This situation perhaps symbolizes the present status of this subject, which is essentially a very small body of facts enveloped in a misty atmosphere of speculation, which is walled off from its surr...

متن کامل

Multiple Model Identification and Control of Neonate Incubators Using Laguerre Basis

This work is focused on temperature and humidity control problem of closed newborn incubators. Such incubator promotes a controlled micro-climate, with small heat transfer between the premature and the environment, leading to a healthful environment. In this context, a laboratory pilot plant (full scale) was built to evaluate control algorithms and this plant is presented here. Furthermore, som...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 43 228  شماره 

صفحات  -

تاریخ انتشار 1968