Practical PET Respiratory Motion Correction in Clinical PET/MR.

نویسندگان

  • Richard Manber
  • Kris Thielemans
  • Brian F Hutton
  • Anna Barnes
  • Sébastien Ourselin
  • Simon Arridge
  • Celia O'Meara
  • Simon Wan
  • David Atkinson
چکیده

UNLABELLED Respiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based correction strategy for PET data affected by respiratory motion and showed that it can improve image quality both for PET acquired simultaneously to the motion-capturing MR and for PET acquired up to 1 h earlier during a clinical scan. METHODS To estimate the respiratory motion, our method needs only an extra 1-min dynamic MR scan, acquired at the end of the clinical PET/MR protocol. A respiratory signal was extracted directly from the PET list-mode data. This signal was used to gate the PET data and to construct a motion model built from the dynamic MR data. The estimated motion was then incorporated into the PET image reconstruction to obtain a single motion-corrected PET image. We evaluated our method in 2 steps. The PET-derived respiratory signal was compared with an MR measure of diaphragmatic displacement via a pencil-beam navigator. The motion-corrected images were compared with uncorrected images with visual inspection, line profiles, and standardized uptake value (SUV) in focally avid lesions. RESULTS We showed a strong correlation between the PET-derived and MR-derived respiratory signals for 9 patients, with a mean correlation of 0.89. We then showed 4 clinical case study examples ((18)F-FDG and (68)Ga-DOTATATE) using the motion-correction technique, demonstrating improvements in image sharpness and reduction of respiratory artifacts in scans containing pancreatic, liver, and lung lesions as well as cardiac scans. The mean increase in peak SUV (SUV(peak)) and maximum SUV (SUV(max)) in a patient with 4 pancreatic lesions was 23.1% and 34.5% in PET acquired simultaneously with motion-capturing MR, and 17.6% and 24.7% in PET acquired 50 min before as part of the clinical scan. CONCLUSION We showed that a respiratory signal can be obtained from raw PET data and that the clinical PET image quality can be improved using only a short additional PET/MR acquisition. Our method does not need external respiratory hardware or modification of the normal clinical MR sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Joint PET-MR respiratory motion models for clinical PET motion correction

Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET da...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications.

UNLABELLED Simultaneous PET and MR imaging is a promising new technique allowing the fusion of functional (PET) and anatomic/functional (MR) information. In the thoracic-abdominal regions, respiratory motion is a major challenge leading to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of gated frames that lead to low signal-to-noise ratio consider...

متن کامل

Joint PET-MR respiratory motion models for clinical PET motion correction.

Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET da...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 56 6  شماره 

صفحات  -

تاریخ انتشار 2015