Theoretical Study of the Spatial Resolution of X-ray Microanalysis in Analytical Electron Microscopy

نویسندگان

  • K. Murata
  • M. Kawamura
  • K. Nagami
چکیده

The spatial resolution of X-ray microanalysis has been investigated by Monte Carlo calculatio~s, including knock-on secondary electron production. The results for AuMa in a lOOOA thin Au film at 100 keV showed an appreciable difference from the ones without knock-out events. Also calculations have been done with the Mott cross-section instead of the screened Rutherford cross-section for elastic scattering. A significant difference was found in the results among the three models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of X-ray Microanalysis in the Study of Diffusion

This paper reviews the use of electron probe microanalysis, scanning electron microscopy and analytical electron microscopy in the measurement of compositional data obtained from diffusion couples. Methods to obtain x—ray spatial resolution as low as mm with the AEM are described. In addition, techniques for improving the detection and for increasing the accuracy of compositional analyses are s...

متن کامل

The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner

Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...

متن کامل

Prospects for Trace Analysis in the Analytical Electron-Microscope

The analytical electron microscope (AEM) uses a high energy (>100 kV) beam of electrons to generate a range of signals from a thin foil sample as shown in figure la [1,2]. Various detectors are configured in the AEM to pick up most of the generated signals (fig. lb). Microanalysis is usually performed using the characteristic x-ray signal, detected by an energy dispersive spectrometer (EDS) alt...

متن کامل

Synthesis and Characterization of Nano-Structure Copper Oxide From Two Different Copper (II) Metal-Organic Framework Precursors

Nano-structured copper oxides were successfully prepared through direct calcination of 1D ladderlike metal-organic framework [Cu2(btec)(2,2'-bipy)2]∞, (btec = 1,2,4,5-benzenetetracarboxylate and 2,2'-bipy = 2,2'-bipyridine) and porous coordination polymer [Cu(BDC)(bipy)](BDCH2), (BDC = 1,4-benzenedicarboxylate; bipy = 4,4'-bipyridine). The nano-structure of the as-synthesized samples are charac...

متن کامل

Low-voltage electron-probe microanalysis of Fe-Si compounds using soft X-rays.

Conventional electron-probe microanalysis has an X-ray analytical spatial resolution on the order of 1-4 μm width/depth. Many of the naturally occurring Fe-Si compounds analyzed in this study are smaller than 1 μm in size, requiring the use of lower accelerating potentials and nonstandard X-ray lines for analysis. Problems with the use of low-energy X-ray lines (soft X-rays) of iron for quantit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017