Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube.

نویسندگان

  • M L Cannon
  • J Cornell
  • D S Tripp-Hamel
  • M A Gentile
  • C L Hubble
  • J N Meliones
  • I M Cheifetz
چکیده

Many ventilators measure expired tidal volume (VT) without compensation either for the compliance of the ventilator circuit or for variations in the circuit setup. We hypothesized that the exhaled VT measured with a conventional ventilator at the expiratory valve would differ significantly from the exhaled VT measured with a pneumotachometer placed at the endotracheal tube. To investigate this we studied 98 infants and children requiring conventional ventilation. We used linear regression analysis to compare the VT obtained with the pneumotachometer with the ventilator-measured volume. An additional comparison was made between the pneumotachometer volume and a calculated effective VT. For infant circuits (n = 70), our analysis revealed a poor correlation between the expiratory VT measured with the pneumotachometer and the ventilator-measured volume (r(2) = 0.54). Similarly, the expiratory VT measured with the pneumotachometer did not correlate with the calculated effective volume (r(2) = 0.58). For pediatric circuits (n = 28), there was improved correlation between the expiratory VT measured with the pneumotachometer and both the ventilator-measured volume and the calculated effective VT (r(2) = 0.84 and r(2) = 0.85, respectively). The data demonstrate a significant discrepancy between expiratory VT measured at a ventilator and that measured with a pneumotachometer placed at the endotracheal tube in infants. Correcting for the compliance of the ventilator circuit by calculating the effective VT did not alter this discrepancy. In conventionally ventilated infants, exhaled VT should be determined with a pneumotachometer placed at the airway.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The esophageal detector device is unreliable when the stomach has been ventilated.

RAPID and accurate diagnosis of the misplacement of an endotracheal tube in the esophagus remains one of the most important problems in anesthesia and intensive care. Clinical signs observed through auscultation, inspection of thoracic excursions, refilling of the breathing bag, or water vapor condensing at the endotracheal tube may be misleading in as many as 30% of patients. ' Although end-ti...

متن کامل

Commentary: Morrow B, Futter M, Argent A. (2006). Effect of endotracheal suction on lung dynamics in mechanically-ventilated paediatric patients.

Endotracheal suctioning is performed regularly in ventilated infants and children to remove obstructive secretions. The effect of suctioning on respiratory mechanics is not known. This study aimed to determine the immediate effect of endotracheal suctioning on dynamic lung compliance, tidal volume, and airway resistance in mechanically-ventilated paediatric patients by means of a prospective ob...

متن کامل

Effect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients

Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...

متن کامل

A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2.

OBJECTIVE The objective of this study was to evaluate a novel method of distal end-tidal CO2 capnography by comparison with PaCO2 and with the more standard method that measures mainstream proximal end-tidal CO2 in intubated infants. METHODS Included in the study were all infants who were ventilated with conventional mechanical ventilation and intubated with a double-lumen endotracheal tube i...

متن کامل

Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume

INTRODUCTION The objective of this laboratory study was to measure the effect of decreased lung compliance and endotracheal tube (ETT) leakage on measured exhaled tidal volume at the airway and at the ventilator, in a research study with a test lung. METHODS The subjects were infant, adult and pediatric test lungs. In the test lung model, lung compliances were set to normal and to levels seen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 162 6  شماره 

صفحات  -

تاریخ انتشار 2000