A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation.
نویسندگان
چکیده
OBJECTIVE To evaluate the efficacy of HBOC-201 for resuscitation of hemorrhagic shock in a swine model incorporating soft tissue injury and delayed evacuation. METHODS A muscle crush injury and 40% estimated blood volume controlled hemorrhage was completed in 24 Yucatan mini-pigs. Pigs were untreated or resuscitated with HBOC-201 or 6% hetastarch (HEX) at 20 min. Invasive hemodynamics and clinical variables were monitored for 4 h (pre-hospital phase) and subsequent fluid infusions were administered for severe hypotension or tachycardia. Animals were recovered from anesthesia and monitored non-invasively to 72 h (hospital phase). RESULTS 100% (8/8) of HBOC-201-, 88% (7/8) of HEX-, and 63% (5/8) of non-resuscitated pigs, survived to 72 h (p=0.27). Mean arterial pressure, mean pulmonary arterial pressure and systemic vascular resistance index were higher in HBOC-201 pigs. By 90 min, cardiac index was restored to baseline in the HBOC-201 group and was 1.4-fold greater than baseline in the HEX group. HBOC-201 pigs had lower fluid requirements than HEX pigs (18.8+/-1.8 and 29.9+/-1.1 ml/kg, p<0.001) in the pre-hospital phase and required fewer blood transfusions (1.3+/-1.3 and 9.4+/-0.6 ml/kg, respectively, p<0.001) in the hospital phase. Urine output and blood creatinine were comparable in HBOC-201 and HEX pigs. Tissue oxygenation levels were highest in the HBOC-201 group. CONCLUSIONS As HBOC-201 restored hemodynamics and tissue oxygenation and decreased fluid requirements, in comparison with HEX, HBOC-201 was at least as efficacious and possibly a superior resuscitative fluid in a military-relevant delayed evacuation hemorrhagic shock swine model.
منابع مشابه
A hemoglobin based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus Hetastarch (HEX) in an uncontrolled liver injury hemorrhagic shock swine model with delayed evacuation.
BACKGROUND As HBOC-201 improves outcome in animals with hemorrhagic shock (HS), we compared HBOC-201 and HEX (used by U.S. military special operations forces) in a swine model of delayed evacuation and uncontrolled HS. METHODS Twenty-four Yucatan pigs underwent a grade III liver injury and were resuscitated with HBOC-201, HEX, or no fluid (NON). Additional infusions were given for hypotension...
متن کاملEffects of bovine polymerized hemoglobin on coagulation in controlled hemorrhagic shock in swine.
HBOC-201, a bovine polymerized hemoglobin, has been proposed as a novel oxygen-carrying resuscitative fluid for patients with hemorrhagic shock (HS). Herein, we evaluated the hemostatic effects of HBOC-201 in an animal model of HS. A 40% blood loss-controlled hemorrhage and soft tissue injury were performed in 24 invasively monitored Yucatan mini-pigs. Pigs were resuscitated with HBOC-201 (HBOC...
متن کاملNitroglycerin attenuates vasoconstriction of HBOC-201 during hemorrhagic shock resuscitation.
BACKGROUND Vasoconstriction, an inherent property of Hemoglobin Based Oxygen Carriers (HBOC) potentially due to nitric oxide (NO) scavenging, may increase cardiovascular complications in HBOC resuscitated trauma patients. The purpose of this study was to determine if co-administration of a weak NO donor, intravenous nitroglycerin (NTG), with HBOC-201 during resuscitation from hemorrhagic shock ...
متن کاملInnate immune response after resuscitation with hemoglobin-based oxygen carrier and recombinant factor VIIA in uncontrolled hemorrhagic shock in a swine model.
BACKGROUND Rapid resuscitation with oxygen-carrying fluids is critically important in hemorrhagic shock (HS) combat casualties in remote areas where blood is not available. Hemoglobin-based oxygen carrier-201 (HBOC-201) has been shown to increase survival and reduce immune activation following HS in animal models. Recombinant factor VIIa (rfVIIa), a systemic hemostatic agent, is Food and Drug A...
متن کاملThe effect HBOC-201 and sodium nitrite resuscitation after uncontrolled haemorrhagic shock in swine.
BACKGROUND Development of Haemoglobin-based oxygen carriers (HBOCs) as blood substitutes has reached an impasse due to clinically adverse outcomes attributed to vasoconstriction secondary to nitric oxide (NO) scavenging. Studies suggest haemoglobin exhibits nitrite reductase activity that generates NO and N(2)O(3); harnessing this property may offset NO scavenging. Therefore, the effects of con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Resuscitation
دوره 66 3 شماره
صفحات -
تاریخ انتشار 2005