Auto-adaptive averaging: detecting artifacts in event-related potential data using a fully automated procedure.
نویسنده
چکیده
The auto-adaptive averaging procedure proposed here classifies artifacts in event-related potential data by optimizing the signal-to-noise ratio. This method rank orders single trials according to the impact of each trial on the ERP average. Then, the minimum residual background noise level in the ERP data is determined at each step in the averaging process. Trials having a negative impact on the residual background noise are discarded from the averaging procedure. Simulations showed that ERP estimates obtained by the auto-adaptive averaging procedure were either better or comparable to those obtained by single trial artifact detection methods at their most optimum configuration, in particular during long duration artifacts. Experimental data from a working memory task further illustrate the effectiveness of the method.
منابع مشابه
A Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept
Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...
متن کاملA fully automated iterative moving averaging (AIMA) technique for baseline correction.
Baseline correction is one of the pre-processing steps in the analysis of metabolite signals from chemometric analytical instruments. Fully automated baseline correction techniques, although more convenient to use, tend to be less accurate than semi-automated baseline correction. A fully automated baseline correction algorithm, the automated iterative moving averaging algorithm (AIMA), is prese...
متن کاملRemoving ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملADAPTIVE ORDERED WEIGHTED AVERAGING FOR ANOMALY DETECTION IN CLUSTER-BASED MOBILE AD HOC NETWORKS
In this paper, an anomaly detection method in cluster-based mobile ad hoc networks with ad hoc on demand distance vector (AODV) routing protocol is proposed. In the method, the required features for describing the normal behavior of AODV are defined via step by step analysis of AODV and independent of any attack. In order to learn the normal behavior of AODV, a fuzzy averaging method is used fo...
متن کاملEvaluation of Hemodynamic Response Function in Vision and Motor Brain Regions for the Young and Elderly Adults
Introduction: Prior studies comparing Hemodynamic Response Function (HRF) in the young and elderly adults based on fMRI data have reported inconsistent findings for brain vision and motor regions in healthy aging. It is shown that the averaging method employed in all previous works has caused this inconsistency. The averaging is so sensitive to outliers and noise. However, fMRI data are o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Psychophysiology
دوره 45 2 شماره
صفحات -