Rapid determination of fosetyl-aluminum residues in lettuce by liquid chromatography/electrospray tandem mass spectrometry.
نویسندگان
چکیده
This paper describes a new method for the sensitive and selective determination of fosetyl-aluminum (Al) residues in vegetable samples. The method involves extraction with water by using a high-speed blender and subsequent injection of the 5-fold diluted extract into the liquid chromatograph. Fosetyl-Al is determined by liquid chromatography with electrospray tandem mass spectrometry after the addition of tetrabutylammonium acetate as the ion-pairing reagent. The method has been used to assay lettuce samples spiked at 2 and 0.2 mg/kg. Recoveries were satisfactory, with mean values of 98 and 106%, respectively, and relative standard deviations were < 10%. The limit of quantitation was 0.2 mg/kg, and the limit of detection was as low as 0.05 mg/kg. Matrix-matched calibration was used for quantitation, and the addition of an internal standard improved repeatability. The developed method allows the accurate and rapid determination of low levels of fosetyl-Al residues in lettuce with very little sample handling and good sensitivity; it was shown to be robust by the analysis of almost 100 samples.
منابع مشابه
Potential of Liquid Chromatography–Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometry for Determination of Fosetyl-aluminium Residues in Dried Hops
P������ J., H������� J., H������� K., N������� K. (2004): Potential of liquid chromatography–atmospheric pressure chemical ionisation tandem mass spectrometry for determination of fosetyl-aluminium residues in dried hops. Czech J. Food Sci., 22: 24–28. New analytical procedure for the determination of fosetyl-aluminium in hop cones (also called “hops”) was developed. Liquid chromatography–atmos...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 86 4 شماره
صفحات -
تاریخ انتشار 2003