Strength of the Cement-Bone Interface Relies More on Interface Contact Than Cement Penetration Depth
ثبت نشده
چکیده
Introduction: In cemented total hip arthroplasty, the implant needs a mechanically stable cement-bone interface for its survival. This can be achieved by adequate cement penetration into the bone lacunar and trabecular spaces. Many studies have been conducted to investigate the strength of the cement-bone interface in relation to the amount of cement penetration, but mainly on a macro-scale [1]. However, to gain a more detailed insight into the mechanical aspects of this geometrically complex interface, the cement-bone interface should be studied on a micro-scale. We developed micro Finite Element (FE) models of the cement-bone interface and varied the cement penetration depth. Subsequently, we loaded the FE models until failure and asked the following questions: (1) Is there a relationship between penetration depth, contact area and strength?; (2) Is the interface stronger in shear than in tension?; (3) How valid are the FE models compared to experimental findings?
منابع مشابه
Mechanical characteristics of the bone-graft-cement interface after impaction allografting.
Impaction allografting is an attractive procedure for the treatment of failed total hip replacements. The graft-cement-host bone interface after impaction allografting has not been characterized, although it is a potential site of subsidence for this type of revision total hip reconstruction. In six human cadaveric femurs, the cancellous bone was removed proximally and local diaphyseal lytic de...
متن کاملExperimental micromechanics of the cement-bone interface.
Despite the widespread use of cement as a means of fixation of implants to bone, surprisingly little is known about the micromechanical behavior in terms of the local interfacial motion. In this work, we utilized digital image correlation techniques to quantify the micromechanics of the cement-bone interface of laboratory-prepared cemented total hip replacements subjected to nondestructive, qua...
متن کاملMechanical properties of a cemented porous implant interface
BACKGROUND Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these co...
متن کاملCement oscillation increases interlock strength at the cement-bone interface, with commentary.
Modern cementing techniques aim to improve the interlock between bone and cement and to establish a durable interface. Cement penetration is generally believed to influence interface failure, but current methods for improving the cement-bone interface are inadequate. Oscillation is the reciprocated movement of an object through its balanced position, or the quantum physics of systematic fluctua...
متن کاملMicromechanics of postmortem-retrieved cement-bone interfaces.
The cement-bone interface plays an important role in load transfer between cemented implant systems and adjacent bone, but little is known about the micromechanical behavior of this interface following in vivo service. Small samples of postmortem-retrieved cement-bone specimens from cemented total hip replacements were prepared and mechanically loaded to determine the response to tensile and co...