SIMDET - Version 4 A Parametric Monte Carlo for a TESLA Detector

نویسنده

  • M. Pohl
چکیده

A new release of the parametric detector Monte Carlo program SIMDET (version 4.01) is now available. We describe the principles of operation and the usage of this program to simulate the response of a detector for the TESLA linear collider. The detector components are implemented according to the TESLA Technical Design Report. All detector component responses are treated in a realistic way using a parametrisation of results from the ab initio Monte Carlo program BRAHMS. Pattern recognition is emulated using a complete cross reference between generated particles and detector response. Also, for charged particles, the covariance matrix and dE/dx information are made available. An idealised energy flow algorithm defines the output of the program, consisting of particles generically classified as electrons, photons, muons, charged and neutral hadrons as well as unresolved clusters. The program parameters adjustable by the user are described in detail. User hooks inside the program and the output data structure are documented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DESY 97-170 Study of e + e − → WW → lνq¯q at 500 GeV

W-pair production in ee annihilation at 500 GeV is studied using different Monte Carlo generators and the proposed detector for the Linear Collider in its TESLA version. Semileptonic W decays are used to give hints for the detector optimization and to determine the expected accuracy of the W mass determination and the measurement of the anomalous triple gauge boson couplings. With an expected l...

متن کامل

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

A performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation

  PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets.   experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the  ...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002