The Evolving Concepts of Haemodynamic Support: From Pulmonary Artery Catheter to Echocardiography and Theragnostics
نویسندگان
چکیده
Echocardiography is a non-invasive tool, aimed towards the anatomical and functional characterization of the heart. In Intensive Care it is considered nowadays as a necessary tool for patient evaluation. However, the information obtained using echocardiography is not the same as provided by other means, namely the invasive ones. In recent years there has been a significant evolution in the general concepts of haemodynamic support for the critically ill patient. In this new environment, echocardiography has gained particular relevance. In this text the new positioning of echocardiography in the light of the new concepts for hemodynamic support is described, as well as, the need for a specific formative program directed towards Intensive Care physicians. A new generation of biomarkers can also add relevant information and start a new era in haemodynamic support. They may help to further characterize the disease process, identifying patients at risk, as well as, characterize specific organ failure as well as monitoring therapy.
منابع مشابه
Continuous assessment of right ventricular ejection fraction: new pulmonary artery catheter versus transoesophageal echocardiography.
In 25 cardiac surgical patients, right ventricular ejection fraction was continuously measured with a new pulmonary artery catheter and transoesophageal echocardiography, scanning the 'fractional area change' in a standardised transatrial cross section area. Measurements were recorded at three predefined time points (pre-, intra-, and postoperatively). Both methods were compared using the Bland...
متن کاملHaemodynamic Monitoring in the Intensive Care Unit: Results from a Web-Based Swiss Survey
BACKGROUND The aim of this survey was to describe, in a situation of growing availability of monitoring devices and parameters, the practices in haemodynamic monitoring at the bedside. METHODS We conducted a Web-based survey in Swiss adult ICUs (2009-2010). The questionnaire explored the kind of monitoring used and how the fluid management was addressed. RESULTS Our survey included 71% of S...
متن کاملHaemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: a comparative study in liver transplant patients.
OBJECTIVE To compare the haemodynamic measurements of cardiac output (CO), central venous pressure (CVP), pulmonary capillary wedge pressure (Pw) and pulmonary artery systolic pressure (PASP), obtained by Swan-Ganz catheter and transthoracic echocardiography. MATERIAL AND METHODS Prospective study in a Medical/Surgical Intensive Care Unit (ICU). A total of 41 post liver transplant patients we...
متن کاملSeries 0advances in Pathobiology, Diagnosis, and Treatment of Pulmonary Hypertension0
Haemodynamic evaluation of pulmonary hypertension. D. Chemla, V. Castelain, P. Hervé, Y. Lecarpentier, S. Brimioulle. #ERS Journals Ltd 2002. ABSTRACT: Pulmonary hypertension is characterised by the chronic elevation of pulmonary artery pressure (PAP) and pulmonary vascular resistance (PVR) leading to right ventricular enlargement and hypertrophy. Pulmonary hypertension may result from respirat...
متن کاملSilent Pulmonary Artery Dissection in a patient with old Pulmonary Balloon Valvuloplasty
Percutaneous pulmonary balloon valvuloplasty (PBV) remains the treatment of choice for pulmonary stenosis (PS). This procedure is effective, safe and gives excellent results. Pulmonary artery (PA) dissection is a rare complication of PBV. This report is a case of an asymptomatic 17-year-old male with a history of PBV due to severe PS dating back to fifteen years ago. During recent echocardiogra...