The reliability of various methods for detecting oesophageal intubation was assessed by means of a single blind study in rats. Both oesophagus and trachea were simultaneously intubated. The presence or absence of various clinical signs was noted during tracheal or oesophageal ventilation and arterial blood gases and end-tidal CO2 were measured. Oesophageal ventilation for one minute was associated with significant decreases (P less than 0.001) in pH, PaO2 and SaO2 and a significant (P less than 0.001) increase in PaCO2. Although mean PaO2 decreased by 70 per cent and mean SaO2 decreased by 31 per cent, 43 percent of rats failed to demonstrate a decrease in SaO2 below 85 per cent. Oxygen saturation was the least reliable method for detecting oesophageal intubation (sensitivity = 0.5, specificity = 0.9, positive predictive value (PPV) = 0.8). Chest movement was the most reliable clinical sign for detecting oesophageal intubation (sensitivity = 0.9, specificity = 1.0, PPV = 1.0). Oesophageal rattle was the second most reliable clinical sign (PPV = 0.9). Moisture condensation in the tracheal tube (PPV = 1.0) and abdominal distension (PPV = 0.9) were judged to be the least reliable because each had a high false negative rate of 0.3. The most reliable method for the early detection of oesophageal intubation in rats was end-tidal, CO2 (sensitivity 1.0, specificity = 1.0, PPV = 1.0). In addition, end-tidal CO2 when used in conjunction with the four clinical signs improved the reliability of these signs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

تأثیر تهویه با حجم‌های جاری متفاوت و تهویه دقیقه‌ای ثابت بر روی دی‌اکسید کربن انتهای بازدمی

Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study  to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2  and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

Cerebral Oxygen Saturation: Graded Response to Carbon Dioxide with Isoxia and Graded Response to Oxygen with Isocapnia

BACKGROUND Monitoring cerebral saturation is increasingly seen as an aid to management of patients in the operating room and in neurocritical care. How best to manipulate cerebral saturation is not fully known. We examined cerebral saturation with graded changes in carbon dioxide tension while isoxic and with graded changes in oxygen tension while isocapnic. METHODOLOGY/PRINCIPAL FINDINGS The...

متن کامل

Pilot study of long‐term anaesthesia in broiler chickens

OBJECTIVE To provide stable anaesthesia of long duration in broiler chickens in order to perform a terminal caecal ligated loop procedure. STUDY DESIGN Prospective experimental study. ANIMALS Seven clinically healthy broiler chickens (Gallus domesticus) aged 27-36 days, weighing 884-2000 g. METHODS Anaesthesia was induced and maintained with isoflurane in oxygen. All birds underwent inter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 1989