Dynamic oxygen-enhanced lung MRI: Cross-correlation analysis and oxygen-activated pixels
نویسندگان
چکیده
Introduction: In oxygen-enhanced MRI (O2-MRI) of the lung, the inhalation of pure oxygen (O2) decreases the longitudinal relaxation time, T1, of blood, which can be detected by T1-weighted MRI [1–9]. Frequently, a block paradigm is used for O2-MRI consisting of a series of T1-weighted scans acquired during alternating blocks with inhalation of room air and O2. This block design results in a signal-time course for each pixel that contains information about lung function as well as respiration and circulation parameters. It has been suggested to evaluate this time course by calculating the cross-correlation coefficient of each pixel response function and the ideal box-car waveform [3]. To quantitatively assess and compare the measured correlation coefficients, the fraction of oxygen-activated pixels has been defined as the fraction of lung pixels with correlation coefficients greater than 0.5 [7,8]. In previous studies [3,7,8], scanning was paused for 1 to 5 minutes after switching the gas supply until the new steadystate signal had been reached. The purpose of the present study was to analyze the properties of the cross-correlation coefficient and of the fraction of oxygen-activated pixels in O2-MRI with continuous scanning, i.e. with pixel time courses that contain the dynamic signal during the wash-in and wash-out periods. Methods: We studied 11 healthy volunteers using a T1-weighting multi-slice inversionrecovery half-Fourier-acquisition single-shot turbo-spin-echo (HASTE) sequence (TI=1300 ms, TE=11 ms, 4 slices, slice thickness 8 mm, slice distance 16 mm, matrix 128×128, FOV 400×400 mm2, GRAPPA acceleration factor 2) implemented on a 1.5-T whole-body scanner (Magnetom Sonata, Siemens Healthcare, Erlangen, Germany) with an 8-channel phased-array thorax coil system. Each examination consisted of a series of 80 acquisitions (20×air, 20×O2, 20×air, 20×O2) with ECG and respiratory triggering for acquisition in end-expiration. Lung tissue was segmented manually in all 11 data sets (44 slices). We used two different reference functions to calculate the cross-correlation coefficient for each pixel time course: a box-car function as in [3,7,8] and a piecewise exponential function (cf. Fig. 1a,b); the wash-in and wash-out time constants of the exponential functions were set to 30 s in agreement with published data [2,4,6,9]. The cross-correlation was calculated for these two original functions and for a set of time-shifted correlation functions (Fig. 1c,d); in the latter case, the maximal correlation coefficient and the corresponding temporal shift over all shifted functions was pixelwise determined. We analyzed the mean values of the cross-correlation coefficients averaged over all volunteers and slices, the fraction of oxygen-activated pixels, and the mean temporal shifts. Cross-correlation coefficients and fractions of oxygen-activated pixels obtained with all reference functions were statistically compared with paired t-tests. Results: The results averaged over all 11 volunteers are summarized in Table 1. The correlation coefficients and the fractions of oxygen-activated pixels were significantly lower (p<0.01) with the fixed rectangular reference function than with all other functions. The highest correlation coefficients were found with the shifted exponential functions. Typical parameter maps are shown in Fig. 2. Table 1: Cross-correlation coefficients, ccc, fractions of oxygen-activated pixels, fOAP, and temporal shifts, Δt; listed are mean values and standard deviations in parentheses Correlation function ccc fOAP (%) Δt (s) Rectangular, fixed (Fig. 1a) 0.452 (0.141) 44.6 (31.3) – Exponential, fixed (Fig. 1b) 0.620 (0.148) 72.7 (22.4) – Rectangular, shifted to maximum, (Fig. 1c) 0.631 (0.120) 76.8 (20.5) 42.3 (12.9) Exponential, shifted to maximum, (Fig. 1d) 0.650 (0.137) 76.9 (21.0) 22.7 (19.5)
منابع مشابه
Functional Lung MRI in Chronic Obstructive Pulmonary Disease: Comparison of T1 Mapping, Oxygen-Enhanced T1 Mapping and Dynamic Contrast Enhanced Perfusion
PURPOSE Monitoring of regional lung function in interventional COPD trials requires alternative endpoints beyond global parameters such as FEV1. T1 relaxation times of the lung might allow to draw conclusions on tissue composition, blood volume and oxygen fraction. The aim of this study was to evaluate the potential value of lung Magnetic resonance imaging (MRI) with native and oxygen-enhanced ...
متن کاملThe change of longitudinal relaxation rate in oxygen enhanced pulmonary MRI depends on age and BMI but not diffusing capacity of carbon monoxide in healthy never-smokers
OBJECTIVE Oxygen enhanced pulmonary MRI is a promising modality for functional lung studies and has been applied to a wide range of pulmonary conditions. The purpose of this study was to characterize the oxygen enhancement effect in the lungs of healthy, never-smokers, in light of a previously established relationship between oxygen enhancement and diffusing capacity of carbon monoxide in the l...
متن کاملDynamic oxygen-enhanced MRI in patients with pulmonary arterial hypertension
Introduction: Oxygen-enhanced MRI (O2-MRI) of the lung is based on the T1-shortening effect of oxygen (O2) inhalation and provides combined information about pulmonary ventilation, perfusion, and diffusion [1–9]. Dynamic O2-MRI acquires (in each pixel) the signal time course influenced by the alternating administration of room air and O2. By fitting a model function (pixelwise) to the acquired ...
متن کاملPharmaceutical Wastewater Chemical Oxygen Demand Reduction: Electro-Fenton, UV-enhanced Electro-Fenton and Activated Sludge
In this study, Chemical Oxygen Demand (COD) from a pharmaceutical wastewater (PhW) was reduced by several techniques such as electro-Fenton (EF), photo electro-Fenton (PEF) and activated sludge (AS) processes and the obtained data were compared with each other. The effects of several parameters such as pH, current density, H2O2/Fe2+ molar ratio, volume ratio of ...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008