Modeling anisotropic undersampling of magnetic resonance angiographies and reconstruction of a high-resolution isotropic volume using half-quadratic regularization techniques
نویسندگان
چکیده
In this paper we address the problem of reconstructing a high resolution volumic image from several low resolution data sets. A solution to this problem is proposed in the particular framework of magnetic resonance angiography (MRA), where the resolution is limited by a trade-o5 between the spatial resolution and the acquisition time, both being proportional to the number of samples acquired in k-space. For this purpose only the meaningful spatial frequencies of the 3D k-space of the vessel are acquired, which is achieved using successive acquisitions with decreased spatial resolution, leading to highly anisotropic data sets in one or two speci8c directions. The reconstruction of the MRA volume from these data sets relies on an edge-preserving regularization method and leads to two di5erent implementations: the 8rst one is based on a conjugate gradient algorithm, and the second one on half-quadratic developments. The hyper parameters of the method were experimentally determined using a set of simulated data, and promising results were obtained on aorta and carotid artery acquisitions, where on the one hand a good 8delity to the acquired data is maintained, and on the other hand homogeneous areas are smooth and edges are well preserved. Half-quadratic regularization proved to be particularly well adapted to the MRA problem and leads to a fast iterative algorithm requiring only scalar and FFT computations. ? 2003 Elsevier B.V. All rights reserved.
منابع مشابه
Magnetic Resonance in Medicine 71:1760–1770 (2014) Monte Carlo SURE-Based Parameter Selection for Parallel Magnetic Resonance Imaging Reconstruction
Purpose: Regularizing parallel magnetic resonance imaging (MRI) reconstruction significantly improves image quality but requires tuning parameter selection. We propose a Monte Carlo method for automatic parameter selection based on Stein’s unbiased risk estimate that minimizes the multichannel k-space mean squared error (MSE). We automatically tune parameters for image reconstruction methods th...
متن کاملQuadratic Regularization Design for 3D Axial CT
While iterative reconstruction (IR) methods have potential advantages over conventional FBP reconstruction such as reduced patient dose and improved noise properties, their use of statistical weighting and space variant scanning geometries can lead to nonuniform and anisotropic spatial resolution. Due to the large number of voxels in the image volume, regularization design methods based on disc...
متن کاملAccelerated Time Resolved Inflow with 3D Multi-Echo Radial Trajectories
Introduction: Arterial spin labeling (ASL) sequences which utilize tagging schemes to images the flow of blood have emerged as effective techniques for the non-contrast angiography; however, these techniques typically suffer from long acquisition times, sensitivity to tag delay parameters, and uncertain performance in cases of complex flow [1-3]. To mitigate these errors, we have previously dem...
متن کاملAn Example-based Approach for High-Resolution Reconstruction of Developing Brain MRI
Imaging moving subjects in early brain development studies remains an open issue for Magnetic Resonance Imaging (MRI). Although the development of ultrafast 2D acquisition sequences has led to significant improvements for clinical studies, the slice acquisition time is still critical and has to be as short as possible to reduce the impact of the motion. As a result, sets of thick 2D slices are ...
متن کاملInfluence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.
BACKGROUND To evaluate the influence of temporal sparsity regularization and radial undersampling on compressed sensing reconstruction of dynamic contrast-enhanced (DCE) MRI, using the iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI technique in the setting of breast cancer evaluation. METHODS DCE-MRI examinations of the breast (n = 7) were conducted using iGRASP at 3 Tesla. Images...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Signal Processing
دوره 84 شماره
صفحات -
تاریخ انتشار 2004