Supporting, microporous, elastomeric, degradable prostheses to improve the arterialization of autologous vein grafts.
نویسندگان
چکیده
Arterial reconstructions with vein grafts fail more frequently than with arterial grafts. One of the causes of graft failure is damage due to overstretching of the graft wall. Overstretching is caused because the vein graft, which has a poorly developed medium, cannot withstand the arterial blood pressures. The aim of this study is to evaluate whether damage due to overstretching can be prevented and a gradual adaptation of the vein graft to the arterial blood pressures can be induced by applying a microporous, elastomeric, degradable prosthesis around the vein graft. Therefore, autologous vein grafts (length 1.0 cm) with and without supporting prostheses (composite vein grafts and control vein grafts, respectively) were interposed into both carotid arteries of rabbits. Microporous, elastomeric, biofragmentable polyurethane-based prostheses and microporous, elastomeric, biodegradable prostheses made of poly-epsilon-caprolactone or a copolymer of epsilon-caprolactone and 3.6-dimethyl-1,4-morpholine-2,5-dione with a monomer ratio of 95.5:4.5 were prepared. The grafts were evaluated up to 6 wk after implantation. The control vein grafts showed severe destructive changes such as de-endothelialization, disruption of the media with oedema, degradation of the elastic laminae and infiltration of polymorphonuclear leucocytes into the vein graft wall, leading eventually to a fibrotic wall. In contrast, the composite vein grafts showed a preservation of the smooth muscle cell layers and the elastic laminae with only few polymorphonuclear leucocytes infiltrated into the vein graft wall.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.
Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipulation or the use of bioreactors to improve their performance. In this study, ...
متن کاملAnti-proliferative and anti-inflammatory effects of topical MAPK inhibition in arterialized vein grafts.
Vein graft failure following bypass surgery is a frequent and important clinical problem. The vascular injury caused by arterialization is responsible for vein graft intimal hyperplasia, a lesion generated by medial smooth muscle cell proliferation and migration into the intima, increased extracellular matrix deposition, and formation of a thick neointima. Development of the neointima into a ty...
متن کاملIn vivo fragmentation of microporous polyurethane- and copolyesterether elastomer-based vascular prostheses.
A previous study showed that microporous, compliant and (bio)degradable vascular prostheses prepared from a polyurethane/poly(L-lactic acid) mixture can function as a temporary scaffold for the regeneration of small-calibre arteries. In this study the mechanism of fragmentation of vascular prostheses made of polyurethane, copolyesterether and blends of either polyurethane or copolyesterether wi...
متن کاملProtection from atherosclerosis in vein grafts by a rigid external support.
Atherosclerosis is a common feature of autogenous vein bypass grafts resulting in their long-term failure. Arterial pressure-induced distension is thought to play a major role in the wall thickening of vein grafts, which may in turn favor atherosclerotic complications. In this study, we evaluated the influence of vein distension on the development of atherosclerotic lesions in jugular vein graf...
متن کاملEnhanced endothelialization of Dacron grafts by external vein wrapping.
The efficacy of external vein wrapping of vascular grafts in promoting the development of a luminal endothelial surface was assessed in 12 dogs who underwent thoracoabdominal bypasses with 26-29 cm X 6-mm i.d. double-velour knitted Dacron grafts. In group I (n = 6) 6-cm segments of the grafts were wrapped with autologous jugular vein with its endothelial surface applied against the outside of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomaterials
دوره 15 2 شماره
صفحات -
تاریخ انتشار 1994