Comparison of the amplitude of the P-wave from intracardiac electrocardiogram obtained by means of a central venous catheter filled with saline solution to that obtained via esophageal electrocardiogram.
نویسندگان
چکیده
Recognition of the P wave is important for the correct characterization of atrial and ventricular arrhythmias. When the P wave is difficult to identify on standard electrocardiography (SECG), either esophageal electrocardiography (EECG) or intracardiac electrocardiography (IC-ECG), central venous catheter may be used. The feasibility of these methods has already been demonstrated, but there is no published study comparing them. This study compared the amplitude of the P wave obtained by IC-ECG with those of the P waves obtained by EECG and SECG. SECG, EECG, and IC-ECG were performed on each patient. IC-ECG and EECG made it possible to register P waves larger than registered by SECG (p <0.00001). The difference between the largest P waves obtained with IC-ECG (5.93 +/- 3.56 mm) and EECG (4.67 +/- 2.16 mm) was not statistically significant (p = 0.1953). In conclusion, IC-ECG is easy to perform and magnifies the P wave at least as effectively as EECG.
منابع مشابه
Determination the Normal Parameters (amplitude and duration) of Electrocardiogram Waves in River Buffaloes (Bubalus Bubalis) of Khuzestan
An easy way to evaluate the cardiovascular system is recording the cardiac electrical activities. Reviewing the available literatures suggests that buffalos ECG compared to other large animals have been neglected and the carried out studies in this field are too limited. Using this method for the diagnosis of cardiac disorders needs the standardization, not only among animal species but also am...
متن کاملElectrocardiogram Assessment in Chough (Pyrrhocorax pyrrhocorax) Following Intranasal Administration of Anesthetics
Objective- The objective of the present study was to define electrocardiographic data following intranasal administration of diazepam, midazolam and xylazine with or without Ketamine in Chough. Design- To determine the heart effects of anesthetics in intranasal administration, an experimental in vivo study was employed. Animals- Ten healthy Choughs were examined in the current study...
متن کاملDepth of Central Venous Catheterization by Intracardiac Electrocardiogram in Adults
BACKGROUND Central venous catheterization is done frequently in cardiac surgery and intensive care settings. Faulty positioning of the catheter can cause many complications. OBJECTIVES The aim of our study was to study the average depth of insertion and formulate a general guideline through the right internal jugular vein (IJV). PATIENTS AND METHODS The right IJV was cannulated over a perio...
متن کاملSkin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections
Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...
متن کاملComparison of the effects of different doses of acepromazine-xylazine on the electrocardiogram in dogs
Seventy seven adult large mixed breed dogs of either sex were included in this study. The animals were randomly divided into four groups and received the following drug combinations intramuscularly: Group 1 xylazine (0.5 mg/kg) and acepromazine (0.05 mg/kg), Group 2 xylazine (0.8 mg/kg) and acepromazine (0.03 mg/kg), Group 3 xylazine (0.3 mg/kg) and acepromazine (0.08 mg/kg) and Group 4 xylazin...