Focused ion beam (FIB) techniques are among the most important tools for the nanostructuring of surfaces. We used the FIB/SEM (scanning electron microscope) for milling and imaging of digestive gland cells. The aim of our study was to document the interactions of FIB with the surface of the biological sample during FIB investigation, to identify the classes of artifacts, and to test procedures that could induce the quality of FIB milled sections by reducing the artifacts. The digestive gland cells were prepared for conventional SEM. During FIB/SEM operation we induced and enhanced artifacts. The results show that FIB operation on biological tissue affected the area of the sample where ion beam was rastering. We describe the FIB-induced surface major artifacts as a melting-like effect, sweating-like effect, morphological deformations, and gallium (Ga(+)) implantation. The FIB induced surface artifacts caused by incident Ga(+) ions were reduced by the application of a protective platinum strip on the surface exposed to the beam and by a suitable selection of operation protocol. We recommend the same sample preparation methods, FIB protocol for milling and imaging to be used also for other biological samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sample preparation for atomic-resolution STEM at low voltages by FIB.

While FIB sample preparation for transmission electron microscopy is a well established technique, few examples exist of samples of sufficient quality for atomic resolution imaging by aberration corrected (scanning) transmission electron microscopy (STEM). In this work we demonstrate the successful preparation of such samples from five different materials and present the refined lift-out prepar...

متن کامل

Cryo-FIB Minimizes Ga Milling Artifacts in Sn

Since FIB was first introduced, one of the major applications has been to mill site-specific crosssectioned sample surfaces [1]. This approach not only allows SEM access to the structural information buried under the surface, but it is also the first step of making TEM lamellae using FIB. Importantly, there are many reports of beam-induced damage due to FIB processing. Here, we report on artifa...

متن کامل

Comparison of different preparation methods of biological samples for FIB milling and SEM investigation.

When a new approach in microscopy is introduced, broad interest is attracted only when the sample preparation procedure is elaborated and the results compared with the outcome of the existing methods. In the work presented here we tested different preparation procedures for focused ion beam (FIB) milling and scanning electron microscopy (SEM) of biological samples. The digestive gland epitheliu...

متن کامل

How to study biological samples by FIB/SEM?

The focused ion beam (FIB)/scanning electron microscope (SEM) is a scanning microscope with an electron column and an ion column embedded in the same specimen chamber; both beams are aiming at the same point on the specimen surface. The FIB, generated by a Ga Liquid Metal Ion Source (LMIS), impacts the sample normal to the surface and can be focused to a spot as small as few nanometres. The FIB...

متن کامل

Investigation of focused ion beam induced damage in single crystal diamond tools

In this work, transmission electron microscope (TEM) measurements and molecular dynamics (MD) simulations were carried out to characterise the focused ion beam (FIB) induced damage layer in a single crystal diamond tool under different FIB processing voltages. The results obtained from the experiments and the simulations are in good agreement. The results indicate that during FIB processing cut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Microscopy research and technique

دوره 70 10  شماره 

صفحات  -

تاریخ انتشار 2007