Value of Three-Dimensional Maximum Intensity Projection Display to Assist in Magnetic Resonance Imaging (MRI)-Based Grading in a Mouse Model of Subarachnoid Hemorrhage

نویسندگان

  • Tomoko Mutoh
  • Tatsushi Mutoh
  • Kazumasu Sasaki
  • Kazuhiro Nakamura
  • Yasuyuki Taki
  • Tatsuya Ishikawa
چکیده

BACKGROUND Subarachnoid hemorrhage (SAH) is one of the most devastating cerebrovascular disorders. We report on the diagnostic value of three-dimensional (3-D) maximum intensity projection (MIP) reconstruction of T2*-weighted magnetic resonance images (MRI), processed using graphical user interface-based software, to aid in the accurate grading of endovascular-perforation-induced SAH in a mouse model. MATERIAL AND METHODS A total of 30 mice were subjected to SAH by endovascular perforation; three (10%) were scored as grade 0, six (20%) as grade 1, six (20%) as grade 2, eight (27%) as grade 3, and seven (23%) as grade 4 according to T2*-weighted coronal slices. In comparison, none of mice were scored as grade 0, eight (27%) as grade 1, five (17%) as grade 2, nine (30%) as grade 3, and eight (27%) as grade 4 based on subsequent evaluation using reconstructed 3-D MIP images. RESULTS Mice scored as grade 0 (10%; no visible SAH) on T2*-coronal images were categorized as grades 1 (thin/localized SAH) and 3 (thick/diffuse SAH) according to 3-D MIP images. Grades based on T2* 3-D MIP images were more closely correlated with conventional SAH score (r2=0.59; P<0.0001) and neurological score (r2=0.25; P=0.005) than those based on T2*-coronal slices (r2=0.46; P<0.0001 for conventional score and r2=0.15; P=0.035 for neurological score). CONCLUSIONS These results suggest that 3-D MIP images generated from T2*-weighted MRI data may be useful for the simple and precise grading of SAH severity in mice to overcome the weakness of the current MRI-based SAH grading system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

New grading system based on magnetic resonance imaging in a mouse model of subarachnoid hemorrhage.

BACKGROUND AND PURPOSE A grading system for experimental subarachnoid hemorrhage (SAH) that does not require animal euthanasia is currently unavailable. We proposed a new grading system based on MRI and evaluated the feasibility of this method in a mouse model of SAH. METHODS SAH was induced by endovascular perforation in adult male C57BL/6 mice. Mice underwent MRI 24 hours after SAH and were...

متن کامل

Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016