A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

نویسندگان

  • Sanjeev Bhatia
  • David M Civitarese
  • Travis Lee Turnbull
  • Christopher M LaPrade
  • Marco Nitri
  • Coen A Wijdicks
  • Robert F LaPrade
چکیده

BACKGROUND Complete radial tears of the medial meniscus have been reported to be functionally similar to a total meniscectomy. At present, there is no consensus on an ideal technique for repair of radial midbody tears of the medial meniscus. Prior attempts at repair with double horizontal mattress suture techniques have led to a reportedly high rate of incomplete healing or healing in a nonanatomic (gapped) position, which compromises the ability of the meniscus to withstand hoop stresses. HYPOTHESIS A newly proposed 2-tunnel radial meniscal repair method will result in decreased gapping and increased ultimate failure loads compared with the double horizontal mattress suture repair technique under cyclic loading. STUDY DESIGN Controlled laboratory study. METHODS Ten matched pairs of male human cadaveric knees (average age, 58.6 years; range, 48-66 years) were used. A complete radial medial meniscal tear was made at the junction of the posterior one-third and middle third of the meniscus. One knee underwent a horizontal mattress inside-out repair, while the contralateral knee underwent a radial meniscal repair entailing the same technique with a concurrent novel 2-tunnel repair. Specimens were potted and mounted on a universal testing machine. Each specimen was cyclically loaded 1000 times with loads between 5 and 20 N before experiencing a load to failure. Gap distances at the tear site and failure load were measured. RESULTS The 2-tunnel repairs exhibited a significantly stronger ultimate failure load (median, 196 N; range, 163-212 N) than did the double horizontal mattress suture repairs (median, 106 N; range, 63-229 N) (P = .004). In addition, the 2-tunnel repairs demonstrated decreased gapping at all testing states (P < .05) with a final measured gapping of 1.7 mm and 4.1 mm after 1000 cycles for the 2-tunnel and double horizontal mattress suture repairs, respectively. CONCLUSION The 2-tunnel repairs displayed significantly less gapping distance after cyclic loading and had significantly stronger ultimate failure loads compared with the double horizontal mattress suture repairs. CLINICAL RELEVANCE Complete radial tears of the medial meniscus significantly decrease the ability of the meniscus to dissipate tibiofemoral loads, predisposing patients to early osteoarthritis. Improving the ability to repair medial meniscal radial tears in a way that withstands cyclic loads and heals in an anatomic position could significantly improve patient healing rates and result in improved preservation of the articular cartilage of the medial compartment of the knee. The 2-tunnel repair may be a more reliable and stronger repair option for midbody radial tears of the medial meniscus. Clinical studies are warranted to further evaluate these repairs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical testing of transcapsular meniscal repair

BACKGROUND All of previous biomechanical studies on meniscal repair have examined the meniscus itself without synovial membrane and capsule, although in the clinical setting, the meniscal repair is generally performed including capsule. Therefore, biomechanical properties of transcapsular meniscal repair are unclear. Thus, this study aimed to clarify the biomechanical properties of transcapsula...

متن کامل

Loop-Post Construct, A Novel Technique for Medial Meniscus Root Repair

Surgical reattachment of medial meniscus posterior root tear (MMPRT) with transtibial sutures can delay the presenceof medial knee joint compartment osteoarthritis. Most suture configurations are placed five mm away from the tornmargin in the meniscal substance which is already degenerated and may decrease the pull out strengths of repairconstruct. The number of meniscus penet...

متن کامل

The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair.

PURPOSE Comparison of the mechanical characteristics of meniscal repair fixation using horizontal sutures and six different sutures under submaximal cyclic and load to failure test conditions may aid physicians in selecting a suture type. METHODS A 2-cm long anteroposterior vertical longitudinal incision was created in six groups of bovine medial menisci. Lesions were repaired using a No. 2 s...

متن کامل

Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study

Transtibial pullout suture (TPS) repair of posterior medial meniscus root (PMMR) tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG) and conventional TPS repair. Twelve porcine tibiae (n = 6 each) TG group: flexor digitorum profundus tendon was passed through an incis...

متن کامل

Human Mesenchymal Stem Cell-derived Exosomes Promote Orderly Cartilage Regeneration in an Immunocompetent Rat Osteochondral Defect Model

Background : Although meniscal repair techniques have developed for several decades, meniscal repair of radial tears still remains challenging issue. For successful meniscal healing of radial tears, primary mechanical stability of meniscal repair is one of the essential requirements. All-inside vertical suture and Cross-suture techniques have been reported to provide superior stability compared...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2016