Three-dimensional transillumination image reconstruction for small animal with new scattering suppression technique.
نویسندگان
چکیده
To realize three-dimensional (3D) optical imaging of the internal structure of an animal body, we have developed a new technique to reconstruct optical computed tomography (optical CT) images from two-dimensional (2D) transillumination images. In transillumination imaging of an animal body using near-infrared light, the image is blurred because of the strong scattering in the tissue. To overcome this problem, we propose a novel technique to apply the point spread function (PSF) for a light source located inside the medium to the transilluminated image of light-absorbing structure. The problem of the depth-dependence of PSF was solved in the calculation of the projection image in the filtered back-projection method. The effectiveness of the proposed technique was assessed in the experiments with a model phantom and a mouse. These analyses verified the feasibility of the practical 3D imaging of the internal light-absorbing structure of a small animal.
منابع مشابه
Comparison of two- and three-dimensional reconstruction methods in optical tomography.
We present a three-dimensional (3D) image reconstruction scheme for optical near-infrared imaging of highly scattering material. The algorithm reconstructs the spatial distribution of the optical parameters of a volume Omega from transillumination measurements on the boundary of Omega. We test the performance of the method for a cylindrical object with embedded absorbing perturbation for a numb...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملMethods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
متن کاملLow-cost three-dimensional imaging system combining fluorescence and ultrasound.
In this paper, we present a dual-modality imaging system combining three-dimensional (3D) continuous-wave transillumination fluorescence tomography with 3D ultrasound (US) imaging. We validated the system with two phantoms, one containing fluorescent inclusions (Cy5.5) at different depths, and another varying-thickness semicylindrical phantom. Using raster scanning, the combined fluorescence/US...
متن کاملA New Guideline for the Allocation of Multipoles in the Multiple Multipole Method for Two Dimensional Scattering from Dielectrics
A new guideline for proper allocation of multipoles in the multiple multipole method (MMP) is proposed. In an ‘a posteriori’ approach, subspace fitting (SSF) is used to find the best location of multipole expansions for the two dimensional dielectric scattering problem. It is shown that the best location of multipole expansions (regarding their global approximating power) coincides with the med...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical optics express
دوره 5 5 شماره
صفحات -
تاریخ انتشار 2014