Guided wave phased-array focusing techniques have been studied and applied in the longrange guided wave inspection of industrial pipelines. Advantages include longer inspection distance, greater wave penetration power and higher detection sensitivity. For reasons of protection, safety and thermal efficiency, a large percentage of pipes are coated and/or encased and buried underground. A phased-array focusing study for guided waves is now considered on pipelines with viscoelastic coatings. In this paper, longitudinal guided wave focusing as well as axisymmetric wave propagation is studied in a bare pipe and a pipe with a viscoelastic coating. A finite element model is studied. First, an investigation on whether the coating has an affect on the axisymmetric guided wave propagation is reported. Based on the result of a single channel, phased array focusing with 8-channel segments is studied. This study provides a very useful tool and guidance for the analysis and examination of guided wave focusing in a real field pipeline under various coating and environmental conditions.
منابع مشابه
Recent Advances on Guided Waves in Pipe Inspection
Guided waves have been increasingly used in nondestructive evaluations. Guided waves have shown to be specially promising in the testing of pipelines and tubing systems due to the ability of propagating long distances. Recent advances on guided wave pipe inspection focus on the understanding and utilization of guided wave flexural modes. This paper discusses and compares the technologies curren...
متن کاملImperial College London University of London Sound Propagation in Lossless Waveguides Coated with Attenuative Materials
Research into ultrasonic guided wave non-destructive testing for the long range inspection of large metallic structures is now well advanced. The main advantage of this method is that a large area can be covered from a given transducer position, so avoiding expensive scanning of all the structure surface. However, in the presence of attenuative coatings the test range can be dramatically reduce...
متن کاملDefect Detection and Imaging from Phased Array Focusing of Ultrasonic Guided Waves
The use of numerical and phased array techniques to focus guided waves and perform inspection of plates and pipes has not been widely used; it represents an interesting solution for defect detection and localization. In addition, imaging of ultrasonic guided wave results using color coded B-Scans is also considered a highly valuable tool for data interpretation. While commercial ultrasonic phas...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...