Effect of vascular occlusion on radiofrequency ablation of the liver: results in a porcine model.

نویسندگان

  • S B Chinn
  • F T Lee
  • G D Kennedy
  • C Chinn
  • C D Johnson
  • T C Winter
  • T F Warner
  • D M Mahvi
چکیده

OBJECTIVE This study determined the effect of vascular occlusion on radiofrequency lesion shape, volume, and temperature in a porcine liver model. SUBJECTS AND METHODS Radiofrequency lesions (n = 33) were created in the livers of six domestic pigs in vivo using a multiprong radiofrequency electrode. Lesions were randomly assigned to one of four vascular occlusion groups: portal vein, hepatic artery, Pringle maneuver (both hepatic artery and portal vein), or no occlusion. Radiofrequency parameters were time, 7 min; power, 50 W; and target temperature, 100 degrees C. Temperatures were measured 5, 10, and 15 mm from the electrode. After the animals were sacrificed, the lesions were excised. Lesion volume, diameter, and shape; maximum temperature; and time exposed to lethal temperatures (42-60 degrees C) were determined. RESULTS Lesion volume was greatest with the Pringle maneuver lesions (12.6 +/- 4.8 cm(3)), followed by occlusion of the portal vein (8.6 +/- 3.8 cm(3)), occlusion of the hepatic artery (7.6 +/- 2.9 cm(3)), and no occlusion (4.3 +/- 1.0 cm(3)) (p < 0.05). Maximum lesion diameter was similar with the Pringle maneuver (3.3 +/- 0.3 cm), the portal vein (3.3 +/- 0.2 cm), and the hepatic artery (3.2 +/- 0.2 cm) groups compared with no occlusion (2.6 +/- 1.0 cm) (p < 0.05). Minimum lesion diameter ranged from 2.9 cm for Pringle maneuver lesions to 1.0 cm for lesions with no occlusion (p < 0.05). Vascular occlusion increased the time tissue was exposed to lethal temperatures (> 42-60 degrees C) and created more spherical lesions than no occlusion. CONCLUSION Vascular occlusion combined with radiofrequency ablation increases the volume of necrosis, creates a more spherical lesion, and increases the time tissue is exposed to lethal temperatures when compared with radiofrequency alone. Most of this vascular occlusion effect could be accomplished with hepatic artery occlusion alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Correction to: Efficacy of Radiofrequency Ablation in Patients with Metastatic Liver Tumors from Breast Carcinoma

In the article published in Volume 27, issue 158, 2017, the Results section in English Abstract have been published incorrectly. The correct Results is given below: &nbsp; Results: The most frequent sizes of mass were 2-4 cm (n=33, 54%) and 4-5 cm (n=23, 38%). Among the patients, 35 (67.3%) had one tumor before, in 11.5% renew tumor happened, and 65.4% had one tumor after treatment. Liver tum...

متن کامل

Thermographic real-time-monitoring of surgical radiofrequency and microwave ablation in a perfused porcine liver model

Radiofrequency ablation (RFA) and microwave ablation (MWA) are currently the dominant modalities to treat unresectable liver tumors. Monitoring the ablation process with b-mode-sonography is often hampered by artefacts. Furthermore, vessels may cause cooling in the adjacent tumor target (heat-sink-effect) with risk of local recurrence. The present study evaluated infrared-thermography to monito...

متن کامل

Evaluation of Success Rate and Complication After Radiofrequency Ablation of Small Saphenous Vein and Simultaneously Sclerotherapy of Its Branches in Patients Referred to Vascular Surgery Clinic 2009-2016

Aims: We aimed to evaluate success rate and complications after radiofrequency ablation of small Saphenous Vein and simultaneously sclerotherapy of its branches in Rasht. Materials and Methods: in this cross-sectional study we followed up the patients with success rate, possible complications including pain, hematoma, thigh and leg paresthesia, neuropathy, Endothermal Heat Induced Thrombosis (...

متن کامل

Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation

BACKGROUND/AIMS Various strategies to expand the ablation zone have been attempted using hepatic radiofrequency ablation (RFA). The optimal strategy, however, is unknown. We compared hepatic RFA with an internally cooled wet (ICW) electrode and vascular inflow occlusion. METHODS EIGHT DOGS WERE ASSIGNED TO ONE OF THREE GROUPS: only RFA using an internally cooled electrode (group A), RFA using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 176 3  شماره 

صفحات  -

تاریخ انتشار 2001