Comparison of the recovery of Mycobacterium bovis isolates using the BACTEC MGIT 960 system, BACTEC 460 system, and Middlebrook 7H10 and 7H11 solid media.

نویسندگان

  • Nichole Hines
  • Janet B Payeur
  • Lorraine J Hoffman
چکیده

The BACTEC Microbacteria Growth Indicator Tube (MGIT) 960 system was evaluated to determine how it compares with the BACTEC 460 radiometric system and solid media for recovery of Mycobacterium bovis from tissue samples. A total of 506 bovine lymph node samples were collected from abattoirs in the United States and Mexico between November 2003 and September 2004. Processed samples were inoculated into an MGIT 960 tube, BACTEC 460 vial, and Middlebrook 7H10 and Middlebrook 7H11 solid media. Ziehl-Neelsen slides were prepared to check for contaminants and confirm the presence of acid-fast positive bacilli. Samples containing acid-fast bacilli were confirmed as members of the Mycobacterium tuberculosis complex by a nucleic acid assay. Niacin and nitrate biochemical tests were used to distinguish M. bovis from M. tuberculosis isolates. Statistical analyses were performed to compare recovery rate, mean time to detection, contamination rates, as well as pair-wise comparisons in each category. The results showed that the MGIT 960 system had a higher recovery rate of M. bovis (122/129) than did the BACTEC 460 (102/129) and solid media system (96/129). The average time to detection was 15.8 days for the MGIT 960 system, 28.2 days for the BACTEC 460 system, and 43.4 days for solid media. Contamination rates were 6.9% for the MGIT 960 system, 3.4% for the BACTEC 460 system, and 21.7% for solid media. These results indicate the MGIT 960 system can be used as an alternative to the BACTEC 460 system for recovering M. bovis from tissue samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.

We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC M...

متن کامل

Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.

The performances of two continuously monitoring mycobacterial culture systems-ESP Culture System II (ESP II; Trek Diagnostics, Inc. , Westlake, Ohio) and BACTEC MGIT 960 (BD Biosciences, Sparks, Md. )-were compared. In addition to both liquid media, all specimens were plated onto Middlebrook 7H11/7H11 selective agar. A total of 3, 151 specimens of all types (56.3% were respiratory specimens) we...

متن کامل

Comparison of the MGIT 960, BACTEC 460 TB and solid media for isolation of Mycobacterium bovis in United States veterinary specimens

BACKGROUND Bacteriologic culture remains one of the most important methods to diagnose bovine tuberculosis despite the lengthy incubation time, significant decontamination and media expense, and high biocontainment requirements. Media selection is an important determination of culture sensitivity, and the planned discontinuation of the BACTEC 460 TB culture system has challenged veterinary diag...

متن کامل

Validation of the use of Middlebrook 7H10 agar, BACTEC MGIT 960, and BACTEC 460 12B media for testing the susceptibility of Mycobacterium tuberculosis to levofloxacin.

Levofloxacin, the active l-isomer of the quinolone ofloxacin, is now widely accepted for treatment of multidrug-resistant tuberculosis. Because the drug is now widely used, we sought to establish susceptibility test conditions for Mycobacterium tuberculosis against levofloxacin by the traditional reference method, agar proportion (AP), the commonly used BACTEC 460 radiometric system, and the ne...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2006