Insufficient penetration of systemic vancomycin into the PermCath lumen.
نویسندگان
چکیده
BACKGROUND Catheter infection is a major cause of morbidity and catheter loss in chronic haemodialysis patients. There has been a large discrepancy in the catheter salvage rate, after an episode of documented bacteraemia, whether the patients receive systemic antibiotic alone or systemic antibiotics concomitant with 'antibiotic-lock technique' (20-30% vs 100%, respectively). To test the hypothesis that vancomycin may not adequately penetrate into the lumen of the catheter, despite therapeutic plasma levels, a series of in-vivo, ex-vivo, and in-vitro experiments were performed. METHODS We compared serum and intralumenal (0.3-0.5 ml aspirate from venous port of the catheter) vancomycin concentrations in 24 chronic haemodialysis patients, with documented bacteraemia, who had received prior systemic vancomycin therapy with 14 similar patients who had additionally received 'vancomycin-lock technique' (100 microg/ml of vancomycin in heparin solution) after each haemodialysis session. RESULTS Despite serum vancomycin concentration of approximately 17 microg/ml in each group, the vancomycin concentration in the venous hub of the catheter was only 0.2+/-0.6 microg/ml in the former group, in sharp contrast to 125. 6+/-13 microg/ml in the latter group. In the ex-vivo experiment, four uninfected PermCaths which had been removed were immediately fixed and studied with scanning electron microscopy. No cellular or fibrin barrier could be found at the terminal pore of the catheter interfering with the diffusion of vancomycin from plasma into the catheter lumen. In the in-vitro experiments, three PermCaths filled with standard heparin solution were incubated for 48 h in 100 ml of plasma containing 20 microg/ml of vancomycin. Vancomycin concentration was measured in 0.3-0.5 ml solution aspirated from each port of the catheters. Vancomycin concentration was 0.2+/-0.1 microg/ml in the aspirated samples. Finally, two PermCaths filled with the standard heparin solution were incubated for 48 h in 100 ml of plasma containing 20 microg/ml of vancomycin, after which the catheters were sectioned at 4-cm intervals. Only the distal 4 cm of the catheters had vancomycin concentrations of 2 and 5 microg/ml, the remaining segments had levels </=0.5 microg/ml. CONCLUSION.: Our results indicate that diffusion of vancomycin from plasma into the haemodialysis catheter is negligible. Thus, haemodialysis patients with central venous catheter who have to be treated for bacteraemia with systemic antibiotic therapy must always receive 'antibiotic-lock technique' of the catheter after each haemodialysis session.
منابع مشابه
The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملPercutaneous replacement of a right jugular dialysis catheter via a stenosed superior vena cava.
A female patient with end-stage renal failure, who was maintained on haemodialysis via multiple central dialysis catheters, developed chronic occlusion of the left brachiocephalic vein. Subsequently, the right jugular dual lumen PermCath became dysfunctional because of marked superior vena cava stenosis. Angioplasty of the superior vena cava stenosis was performed but failed to restore adequate...
متن کاملFour cases of adhered permanent double lumen hemodialysis catheters (Permcath).
Between September 2010 and January 2012, four patients in our hospital were observed to have permanent dialysis catheters that adhered to either the SVC or right atrium. The first patient underwent intraoperative fluoroscopy and was scheduled for cardiac surgery. Unfortunately due to metabolic disturbances, the patient's condition deteriorated and she died before surgery. The second patient un...
متن کاملAdministration of Vancomycin at High Doses in Patients with Post Neurosurgical Meningitis: A Comprehensive Comparison between Continuous Infusion and Intermittent Infusion
Poor penetration of vancomycin into Central Nervous System (CNS) can lead to treatmentfailure. The aim of this study was to evaluate and compare CSF concentration and serumpharmacokinetics of high dose vancomycin by continuous infusion vs. intermittent infusion inpost neurosurgical meningitis patients. Twenty patients were divided into two groups. Patientsin intermittent infusion group received...
متن کاملAdministration of Vancomycin at High Doses in Patients with Post Neurosurgical Meningitis: A Comprehensive Comparison between Continuous Infusion and Intermittent Infusion
Poor penetration of vancomycin into Central Nervous System (CNS) can lead to treatmentfailure. The aim of this study was to evaluate and compare CSF concentration and serumpharmacokinetics of high dose vancomycin by continuous infusion vs. intermittent infusion inpost neurosurgical meningitis patients. Twenty patients were divided into two groups. Patientsin intermittent infusion group received...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 15 7 شماره
صفحات -
تاریخ انتشار 2000