Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture.

نویسندگان

  • Masahiro Iikubo
  • Kaoru Kobayashi
  • Akira Mishima
  • Shinji Shimoda
  • Takayoshi Daimaruya
  • Chinami Igarashi
  • Masahiro Imanaka
  • Masao Yuasa
  • Maya Sakamoto
  • Takashi Sasano
چکیده

OBJECTIVE The accuracies of intraoral radiography (IOR), multidetector helical computerized tomography (MDHCT) at slice thicknesses 0.63 mm and 1.25 mm, and limited cone-beam computerized tomography (LCBCT) were compared for detection of horizontal tooth root fracture. STUDY DESIGN In 7 beagle dogs, 28 maxillary anterior teeth were used, of which 13 had artificially induced horizontal root fracture. The specimens were examined by the above-mentioned 4 modalities. Diagnosis of root fracture was based on direct visualization of radiolucent line in each image by 6 radiologists. RESULTS Sensitivity, negative predictive value, and diagnostic accuracy (true positives + true negatives) for detecting fracture lines in LCBCT (0.96 +/- 0.04, 0.97 +/- 0.03, 0.93 +/- 0.04, respectively) were significantly higher than MDHCT at 0.63 mm (0.76 +/- 0.09, 0.8 +/- 0.05, 0.8 +/- 0.05, respectively), MDHCT at 1.25 mm (0.49 +/- 0.09, 0.66 +/- 0.04, 0.69 +/- 0.05, respectively), and IOR (0.51 +/- 0.18, 0.67 +/- 0.08, 0.69 +/- 0.08, respectively). Specificity and positive predictive value showed no significant intermethod difference among the 4 modalities. CONCLUSION Limited cone-beam CT is more useful than the other 3 radiographic modalities for diagnostic imaging of horizontal tooth root fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

OBJECTIVES This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. MATERIALS AND METHODS Mesial and distal roots of 72 recently extracted molar were endodonticall...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Comparison of the Diagnostic Accuracy of Digital Intraoral Radiography with PSP and CBCT in the Detection of Horizontal and Vertical Dental Root Fractures

Background and Aim: Clinical and radiographic diagnoses of dental root fractures have always been difficult and require high accuracy in dental care and treatment. The aim of this study was to compare the diagnostic accuracy of intraoral digital radiography (PSP) and CBCT in the detection of horizontal and vertical root fractures (HRF and VRF). Materials and Methods: For this experimental stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 108 5  شماره 

صفحات  -

تاریخ انتشار 2009