Automated preparation of whole blood-derived platelets suspended in two different platelet additive solutions and stored for 7 days.
نویسندگان
چکیده
BACKGROUND The Atreus system (Terumo BCT) automates the preparation of blood components from whole blood donations. Intermediate platelet (PLT) products can be pooled manually or with the OrbiSac (Terumo BCT) and suspended in different PLT additive solutions (PASs) to obtain PLT concentrates (PCs). The aim of our study was to compare the in vitro PLT quality of PCs obtained with either the Atreus 2C+ and the OrbiSac or the Atreus 3C and suspended in PAS-II or PAS-IIIM during storage for up to 7 days. STUDY DESIGN AND METHODS We prepared eight PCs from buffy coats obtained with Atreus 2C+, pooled with the OrbiSac, and suspended in PAS-II and eight PCs from interim PLT units obtained with the Atreus 3C and suspended either in PAS-II or in PAS-IIIM. We measured volume, PLT content, and mean PLT component and performed metabolic assays (pH, glucose, lactate, pO₂, and pCO₂) and flow cytometry analyses (GPIb, GPIIbIIIa, GPIV, CD62P, CD63, von Willebrand factor [vWF], fibrinogen, Factor V, and annexin V). RESULTS PCs prepared with the Atreus 3C showed lower volume and higher PLT concentration when compared with PCs prepared with the Atreus 2C+ and the OrbiSac (p < 0.05). Glucose consumption rate and the expression of CD62P, CD63, and vWF were lower in PCs suspended in PAS-IIIM when compared with PCs suspended in PAS-II (p < 0.05). CONCLUSION PCs prepared with the Atreus 3C and suspended in PAS-IIIM preserve satisfactorily the in vitro PLT quality during 7-day storage. PLT activation during a 7-day storage period was lower when the storage solution was PAS-IIIM in comparison with PAS-II.
منابع مشابه
An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage
Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...
متن کاملEvaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage
Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملEvaluation of Biochemical Parameters of Platelet Concentrates Stored in Plasma or in A Platelet Additive Solution (Composol)
Abstract Objective Removing plasma from the platelet concentrate (PC) medium could be an effective way to increase the safety of this product. The goal of this study was to compare PC stored in plasma or in an additive solution (Composol) with in vitro testing. Materials and Methods Fifty-four single donor PCs were prepared from Iranian Blood Transfusion Organization (IBTO). Each PC unit wa...
متن کاملPotatoes: Source of Laboratory Reagent for Human Platelets Research
Irish potatoes is rich in carbohydrate, with varied glucose levels. It is also a very good source of apyrase, an enzyme used for platelet storage. The aim of this study was to explore Irish potatoes as an easily available source for apyrase extraction and purification. Apyrase was extracted from 5 Kg of Irish potatoes. Platelets were derived from 5-10 ml of human whole blood and G6PD activity w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transfusion
دوره 54 2 شماره
صفحات -
تاریخ انتشار 2014