Pulmonary NO synthase inhibition and inspired CO2: effects on V'/Q' and pulmonary blood flow distribution.
نویسندگان
چکیده
Inhaled carbon dioxide decreases ventilation/perfusion ratio (V'/Q') heterogeneity in dogs. The aim of this study was to test whether inhaled CO2 improves the V'/Q' by inhibition of nitric oxide production and whether inhibition of endogenous NO production in the lung alters gas exchange and V'/Q' matching. Eleven healthy dogs were anaesthetized and mechanically ventilated. The multiple inert gas elimination technique (MIGET) was used to measure V'/Q' heterogeneity and regional pulmonary blood flow heterogeneity was assessed in five dogs using fluorescent microspheres. In a separate set of five dogs, exhaled NO levels were measured via chemiluminescence. All dogs were studied before and after 4.8% inspired CO2, and then given the NO synthase inhibitor N(omega)-nitro-L-arginine methyl ester (L-NAME, 10 mg x kg(-1)) via nebulization, after which they were studied again with room air and inhaled CO2. CO2 and L-NAME improved arterial and alveolar oxygen tension, but the improvements with L-NAME did not reach statistical significance. Improved V'/Q' matching, as assessed by the MIGET, occurred under all experimental conditions. Exhaled NO levels were reduced by 40% with CO2 and 70% with L-NAME. The standard deviation of regional pulmonary blood flow assessed via microspheres decreased only with inhaled CO2. Fractal analysis of pulmonary blood flow distributions revealed that regional blood flow was highly correlated with flow to neighbouring pieces of lung in all four conditions with no changes in the fractal dimension. Inspired carbon dioxide improves ventilation perfusion ratio matching and is associated with a more homogeneous distribution of pulmonary blood flow. Although inspired carbon dioxide causes a reduction in exhaled nitric oxide, the differences in pulmonary perfusion distributions found between carbon dioxide and N(omega)-nitro-L-arginine methyl ester suggest that the carbon dioxide effect is not mediated by a reduction in nitric oxide production. The improved ventilation perfusion ratio matching with inhibition of nitric oxide synthase suggests the intriguing possibility requiring further study that endogenous production of nitric oxide in the lung does not subserve ventilation perfusion ratio regulation.
منابع مشابه
PULMONARY VASCULAR MUSCLE PROLIFERATION AS A RESULT OF PROTEIN AND mRNA-eNOS ALTERATIONS IN A RAT MODEL OF CHF
Endothelial Nitric Oxide Synthase (eNOS) produces nitric oxide (NO) from L-arginine and is important for the maintenance of cardiovascular homeostasis. Congestive heart failure (CHF) generally results in increased pulmonary blood flow and if untreated leads to pulmonary hypertension and end stage heart failure. We therefore hypothesized that increased pulmonary flow without changes in pres...
متن کاملEffect of inhaled nitric oxide on pulmonary function after sepsis in a swine model.
BACKGROUND Inhaled nitric oxide (NO) has been shown to improve sepsis induced pulmonary dysfunction. This study evaluated the mechanism by which inhaled NO improves pulmonary function in a porcine sepsis model. METHODS After an infusion of Escherichia coli lipopolysaccharide (LPS, 200 micrograms/kg), animals were resuscitated with saline solution (1 ml/kg/min) and observed for 3 hours while m...
متن کاملHemodilution during venous gas embolization improves gas exchange, without altering V(A)/Q or pulmonary blood flow distributions.
BACKGROUND Isovolemic anemia results in improved gas exchange in rabbits with normal lungs but in relatively poorer gas exchange in rabbits with whole-lung atelectasis. In the current study, the authors characterized the effects of hemodilution on gas exchange in a distinct model of diffuse lung injury: venous gas embolization. METHODS Twelve anesthetized rabbits were mechanically ventilated ...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملبررسی شکل منحنی جریان و حجم در ضایعات انسدادی کارینا و برونش
Spirometry and flow - volume loop show the abnormal pattern of pulmonary dysfunction and the site of the obstruction of upper and peripheral airways. For determinig the shape of flow - volume loop in obstruction of carina and bronchus we examined 19 patients with large airway obstruction documented with fiberoptic bronchoscopy via pulmonary function testing and flow volume loop performing. Two...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2000