This paper analyses the influence of horizontal bracing restraints provided by the friction between pallet bases and rail beams on the static behaviour and design of steel drive-in storage racks. The pallet bracing restraints are shown to significantly influence the structural behaviour of the rack, and their effect on the bending moment distribution of the uprights is studied in the paper. The 2D single upright model proposed by Godley is improved in this study by including the restraints provided by the plan flexural stiffness of the rail beams and the friction between the pallets and rail beams. The improved 2D model was found to accurately reproduce the bending moment distributions obtained using 3D advanced finite element analysis. The 2D single upright model is used to analyse 36 drive-in racks under various load case combinations. The paper evaluates the influence of the pallet bracing restraints on the ultimate capacity of drive-in racks, clarifies the loading pattern(s) governing the structural design and determines the friction coefficient, or strength of a restraining device, required to prevent the pallets from sliding. It is shown that while restraints from pallets could potentially be considered in design, they would not lead to more economic structural solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bolted moment connections in drive-in and drive-through steel storage racks

Often unbraced, the stability of steel storage racks may depend solely on the pallet beam to upright connector and on the stiffness of the base plate to floor connection ([1]). This paper presents experimental results from cyclic tests performed on portal beam to upright bolted moment connections intended for cold-formed steel drive-in and drive-through storage racks. In storage racks, portal b...

متن کامل

Comparative Review of the Performance Based Design of Building Structures Using Static Non-Linear Analysis, Part A: Steel Braced Frames

The objective of this review to be submitted in two independent parts, for steel frames and for RC frames, is to compare their structural performance with respect to the proposed N2-method, and so also of the consequent convenience of using pushover methodology for the seismic analysis of these structures. A preliminary investigation is presented on a pushover analysis used for the seismic perf...

متن کامل

Electrochemical and Tribological Behaviour of Oxide Dispersion Strengthened Duplex Stainless Steel in Mine Water Environment

Abstract This work investigated the electrochemical and aqueous tribological behavior of hot pressed 2205 duplex stainless steel (DSS). DSS sintered composites of different volume percent (% vol) of partially stabilized zirconia (PSZ) was developed using powder metallurgy (PM) technique. Electrochemical behaviour was studied at room temperature, using open circuit potential and potentiody...

متن کامل

Comparative Review of the Performance Based Design of Building Structures Using Static Non-Linear Analysis, Part B: R/C Frames

The objective of this review to be submitted in two independent parts, for steel frames and for RC frames, is to compare their structural performance with respect to the proposed N2-method, and so also of the consequent convenience of using pushover methodology for the seismic analysis of these structures. A preliminary investigation is presented on a pushover analysis used for the seismic perf...

متن کامل

The Relative Performance of New and Used Gma Wood Pallets

Test Methods A total of 1867 new, multiple-use and used (remanufactured and repaired) GMA pallets were randomly sampled from 20 different locations throughout the United States. The pallets were carefully inspected and then tested for strength and stiffness when in racks spanning the stringers (RAS) and spanning the deckboards (RAD). The test spans were 44and 36-inch respectively and a uniform-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017