Early bacterial colonization and soft tissue health around zirconia and titanium abutments: an in vivo study in man.
نویسندگان
چکیده
AIM To compare the early bacterial colonization and soft tissue health of mucosa adjacent to zirconia (ZrO(2)) and titanium (Ti) abutment surfaces in vivo. MATERIALS AND METHODS Twenty edentulous subjects received two endosseous mandibular implants. The implants were fitted with either a ZrO(2) or a Ti abutment (non-submerged implant placement, within-subject comparison, left-right randomization). Sulcular bacterial sampling and the assessment of probing pocket depth, recession and bleeding on probing were performed at 2 weeks and 3 months post-surgery. Wilcoxon matched-pairs, sign-rank tests were applied to test differences in the counts of seven marker bacteria and the clinical parameters that were associated with the ZrO(2) and Ti abutments, at the two observation time points. RESULTS ZrO(2) and Ti abutments harboured similar counts of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, Peptostreptococcus micros, Fusobacterium nucleatum and Treponema denticola at 2 weeks and 3 months. Healthy clinical conditions were seen around both ZrO(2) and Ti abutments at all times, without significant differences in most clinical parameters of peri-implant soft tissue health. Mean probing depths around Ti abutments were slightly deeper than around ZrO(2) abutments after 3 months (2.2 SD 0.8 mm vs. 1.7 SD 0.7 mm, P=0.03). CONCLUSIONS No difference in health of the soft tissues adjacent to ZrO(2) and Ti abutment surfaces or in early bacterial colonization could be demonstrated, although somewhat shallower probing depths were observed around ZrO(2) abutments after 3 month.
منابع مشابه
Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study
PURPOSE Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard su...
متن کاملSoft tissue response to zirconia and titanium implant abutments: an in vivo within-subject comparison.
AIM To compare the health of the soft tissues towards zirconia and titanium abutments in man, as observed using histological data. MATERIAL AND METHODS Twenty patients received two mandibular implants with either a zirconia or titanium abutment (split mouth study design, left-right randomization). After 3 months soft tissue biopsies were prepared for histological evaluation. They were subject...
متن کاملAnalysis of the peri-implant soft tissues in contact with zirconia abutments: an evidence-based literature review.
AIM The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. BACKGROUND Metallic abutments can provide grayish color wh...
متن کاملZirconia as a dental implant abutment material: a systematic review.
PURPOSE The focus of this systematic review was to assess the published data concerning zirconia dental implant abutments from various aspects. MATERIALS AND METHODS To identify suitable literature, an electronic search was performed using PubMed. The keywords "zirconia," "zirconium," "ceramic," "dental abutments," "dental implants," "plaque," and "bacteria" were included. Titles and abstract...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 22 6 شماره
صفحات -
تاریخ انتشار 2011