C-arm CT measurement of cerebral blood volume: an experimental study in canines.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT). MATERIALS AND METHODS CBV was measured in 12 canines by using PCT and C-arm CT. Two measurements with each technique were made on each animal; a different injection protocol was used for each of these techniques. PCT was performed by using a 64-section V-scanner. C-arm CT was performed by using a biplane Artis dBA system. PCT images were transferred to a commercially available workstation for postprocessing and analysis; C-arm CT images were transferred to a commercially available workstation for postprocessing and analysis by using prototype software. From each animal, 2 sections from each technique were selected for analysis. RESULTS There was good agreement of both the color maps and absolute numbers between the 2 techniques. The maximum and mean deviations of values between the 2 techniques for the first 5 animals were 30.20% and 7.82%; for the second 7 animals, these values were 26.79% and 7.40%. The maximum and mean deviations between the 2 C-arm CT studies performed on the first 5 animals were 33.15% and 12.24%; for the second 7 animals, these values were 41.15% and 10.89%. CONCLUSIONS In these healthy animals, measurement of CBV with C-arm CT compared well with measurements made with PCT.
منابع مشابه
C-arm CT measurement of cerebral blood volume in ischemic stroke: an experimental study in canines.
BACKGROUND AND PURPOSE CBV is a key parameter in distinguishing penumbra from ischemic core. The purpose of this study was to compare CBV measurements acquired with standard PCT with ones obtained with C-arm CT in a canine stroke model. MATERIALS AND METHODS Under an institutionally approved protocol, unilateral MCA strokes were created in 10 canines. Four hours later, DWI was used to confirm...
متن کاملC-arm CT measurement of cerebral blood volume using intra-arterial injection of contrast medium: an experimental study in canines.
BACKGROUND AND PURPOSE Measurement of perfusion parameters is typically done using an intravenous injection of contrast medium. This purpose of this study was to evaluate the feasibility of measuring regional and global CBV using C-arm CT with IA injections of contrast medium. MATERIALS AND METHODS Twelve canines were studied. CBV measurement was performed using standard PCT, and then using C...
متن کاملC-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.
BACKGROUND AND PURPOSE Assessment of perfusion parameters is important in the selection of patients who are most likely to benefit from revascularization after an acute ischemic stroke. The aim of this study was to evaluate the feasibility of measuring cerebral perfusion parameters with the use of a novel high-speed C-arm CT acquisition in conjunction with a single intravenous injection of cont...
متن کاملUsing a C-arm CT for Interventional Perfusion Imaging: A Phantom Study to Measure Linearity Between Iodine Concentration and Hounsfield Values
In this work we present phantom measurements to determine the relationship between iodine concentration and measured Hounsfield unit (HU) value using a clinical C-arm CT. These measurements support our current work to use a C-arm CT for brain perfusion imaging in the interventional suite which could e.g. optimize the workflow during stroke therapy. For perfusion imaging a linear relationship be...
متن کاملC-Arm Flat Detector CT Parenchymal Blood Volume Thresholds for Identification of Infarcted Parenchyma in the Neurointerventional Suite.
BACKGROUND AND PURPOSE C-arm flat detector CT parenchymal blood volume imaging allows functional assessment of the brain parenchyma in the neurointerventional suite. This study aimed to determine the optimal C-arm flat detector CT parenchymal blood volume thresholds for demarcating irreversibly infarcted brain parenchyma by using areas of restricted diffusion on MR imaging as a surrogate marker...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2009