Continuous monitoring of dynamic pulmonary compliance enables detection of endobronchial intubation in infants and children.

نویسندگان

  • Aman Mahajan
  • Nir Hoftman
  • Angela Hsu
  • Robert Schroeder
  • Samuel Wald
چکیده

BACKGROUND Auscultation of breath sounds is used routinely to confirm tracheal placement of endotracheal tubes (ETT). In infants and children, this method is limited by the conduction of breath sounds bilaterally, despite endobronchial intubation. Although several methods of detecting endobronchial intubation have been described, none is both simple and reliable. In this investigation, we determined whether changes in pulmonary compliance and airway pressures, measured using continuous side stream spirometry, can reliably detect endobronchial intubation in pediatric patients. METHODS Forty patients aged 1 month to 6 years were included. After endotracheal intubation the ETT was incrementally advanced as two observers monitored breath sounds and spirometry (Pressure-Volume Loops). Changes in pulmonary compliance, peak inspiratory pressure, or auscultation were reported, at which point ETT position was confirmed by fiberoptic bronchoscopy. RESULTS Endobronchial intubation decreased measured pulmonary compliance by 45 +/- 11% (mean +/- sd; P < 0.001, Range 26%-66%) and increased peak airway pressures by 26 +/- 17% (mean +/- sd; P < 0.001, Range 0-87). Changes in peak airway pressures were smaller and more variable when compared to changes in compliance. Breath-sound auscultation failed to detect endobronchial intubation in 7.5% of cases. CONCLUSIONS Pulmonary compliance changes are a sensitive and an accurate indicator of endobronchial intubation in infants and children. Both increased peak airway pressures and changes in breath sounds are less sensitive indicators of endobronchial intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA

    Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...

متن کامل

Proposing an Intelligent Monitoring System for Early Prediction of Need for Intubation among COVID-19 Hospitalized Patients

Introduction: Predicting acute respiratory insufficiency due to coronavirus disease 2019 (COVID-19) can diminish the severe complications and mortality associated with the disease. This study aimed to develop an intelligent system based on machine learning (ML) models for frontline clinicians to effectively triage high-risk patients and prioritize who needs mechanical intubation (MI). Material...

متن کامل

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

Endobronchial Tuberculosis and Chest Radiography

Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1) published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiograp...

متن کامل

Monitoring lung compliance and end-tidal oxygen content for the detection of venous air embolism.

Venous air embolism (VAE) is a recognized complication of surgery performed with the patient in the sitting position, but it occurs also during other operations. We report two cases of VAE, associated with a notable decrease in dynamic lung compliance, detected by side-stream spirometry. Based on these cases, an experiment with 10 pigs was designed to evaluate the usefulness of side-stream spir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 105 1  شماره 

صفحات  -

تاریخ انتشار 2007