Monitoring polynuclear aromatic hydrocarbons in aqueous environments with passive low-density polyethylene membrane devices.

نویسندگان

  • Mark G Carls
  • Larry G Holland
  • Jeffrey W Short
  • Ron A Heintz
  • Stanley D Rice
چکیده

Low-density polyethylene membranes, typically filled with triolein, have been previously deployed as passive environmental samplers designed to accumulate nonpolar hydrophobic chemicals from water, sediments, and air. Hydrocarbons in such samplers, known as semipermeable membrane devices (SPMDs), diffuse through pores in the membranes and are trapped in the central hydrocarbon matrix, mimicking uptake by living organisms. Here, we describe laboratory and field verification that low-density polyethylene membrane devices (PEMDs) without triolein provide reliable, relatively inexpensive, time-integrated hydrocarbon sampling from water. For comparison, polynuclear aromatic hydrocarbon (PAH) uptake in SPMDs and pink salmon eggs also was studied. Total concentrations of PAH accumulated by PEMDs were highly correlated with concentrations in water (r2 > or = 0.99) and linear over the range tested (0-17 microg/L). Higher-molecular-mass PAH preferentially accumulated in PEMDs and in pink salmon eggs, but the source of oil in PEMDs remained identifiable. Accumulations of PAH were highly similar to those in SPMDs. The PEMDs retained approximately 78% of accumulated total PAH for 40 d in clean water. Thus, a simple plastic membrane can be conveniently used for environmental monitoring, particularly during situations in which contaminant concentrations are low (in the parts-per-billion range), variable, and intermittent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polyethylene devices: passive samplers for measuring dissolved hydrophobic organic compounds in aquatic environments.

We demonstrate the use of polyethylene devices (PEDs) for assessing hydrophobic organic compounds (HOCs) in aquatic environments. Like semipermeable membrane devices (SPMDs) and solid-phase microextraction (SPME), PEDs passively accumulate HOCs in proportion to their freely dissolved concentrations. Polyethylene-water partition constants (K(PEW)S) were measured in the laboratory for eight polyc...

متن کامل

Improvements in pollutant monitoring: optimizing silicone for co-deployment with polyethylene passive sampling devices.

Sequestering semi-polar compounds can be difficult with low-density polyethylene (LDPE), but those pollutants may be more efficiently absorbed using silicone. In this work, optimized methods for cleaning, infusing reference standards, and polymer extraction are reported along with field comparisons of several silicone materials for polycyclic aromatic hydrocarbons (PAHs) and pesticides. In a fi...

متن کامل

Significant spatial variability of bioavailable PAHs in water column and sediment porewater in the Gulf of Mexico 1 year after the Deepwater Horizon oil spill.

One year after the Deepwater Horizon oil spill accident, semipermeable membrane devices (SPMDs) and polyethylene devices (PEDs) were deployed in wetland areas and coastal areas of the Gulf of Mexico (GOM) to monitor polycyclic aromatic hydrocarbons (PAHs). The measured PAH levels with the PEDs in coastal areas were 0.05-1.9 ng/L in water and 0.03-9.7 ng/L in sediment porewater. With the SPMDs, ...

متن کامل

Chronic exposure to polynuclear aromatic hydrocarbons in natal habitats leads to decreased equilibrium size, growth, and stability of pink salmon populations.

The immediate and delayed effects of embryonic exposure to low levels of polynuclear aromatic hydrocarbons (PAHs) have been shown to reduce survival to maturity by 50% in exposed pink salmon populations. This suggests that chronically exposed populations could be extirpated over relatively few generations, but the effect of density dependence on extirpation rate is unknown. This study examines ...

متن کامل

Modeling Compound Loss from Polydimethylsiloxane Passive Samplers

Volatile losses were measured from polydimethylsiloxane (PDMS) passive samplers during determination of contaminant porewater concentrations in sediments. Volatile losses could occur between the time of retrieval and processing of the passive sampler or in intertidal environments where the passive sampler could potentially be exposed above the water surface at low tide. A model was developed to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental toxicology and chemistry

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2004