Conventional methods of caries detection, including the gold standard of histological examination, have certain disadvantages that must be addressed prior to validating any other diagnostic technique-current or new. Here we evaluated the validity of micro-computed tomography (micro-CT) as an alternative gold-standard technique for caries detection. Sixty teeth with suspected occlusal caries were chosen from a pool of teeth extracted for orthodontic, periodontal, or surgical reasons. Identical reference points were marked on photographs taken for teeth and were used to evaluate each method. Dimensions of caries were assessed by two calibrated examiners using the ICDAS-II visual examination system, bitewing radiographs, and micro-CT. The teeth included in the study were selected randomly from solution before all measurements. For micro-CT, the device was set to 50 kV, 800 µA, pixel size 15 µm (at 1024 × 1024 resolution), and 1° rotation step. NRecon software (SkyScan) was used to obtain reconstructed images. For each diagnostic method, results were compared with histology results using the McNemar test. Receiver operator characteristic (ROC) analysis was also performed for each method (Z-test; p < 0.05). Besides showing a high correlation with histology results, micro-CT yielded the greatest values at the D3 threshold; moreover, accuracy and area under the ROC curve (AUC) values were greatest at the D1threshold. Our results indicate that micro-CT performs as well as or better than histological examination for the purpose of comparing methods for caries detection.
منابع مشابه
Diagnostic accuracy of cone-beam computed tomography in detecting secondary caries under composite fillings: an in vitro study
PURPOSE The aim of this in vitro study was to assess the diagnostic performance of cone-beam computed tomography (CBCT) in the detection of secondary carious lesions under composite resin fillings applied to different types of cavities. MATERIALS AND METHODS Occlusal cavities (O) (n=18), occlusal cavities with mesial or distal component (MO/DO) (n=30), and mesial-occlusal-distal cavities (MOD...
متن کاملMicro-computed tomography of a 500-year-old tooth: technical note.
OBJECTIVE To determine whether micro-computed tomography (micro-CT) could be used to reconstruct ancient dental anatomy accurately and differentiate the enamel from the dentin, as well as to verify whether micro-CT could detect tooth disorders such as attrition or caries accurately. METHODS Micro-CT imaging was performed, using a cone-beam micro-CT specimen scanner, on a 500-year-old human to...
متن کاملAlternative methods to visual and radiographic examinations for approximal caries detection.
A shift in caries prevalence from occlusal surfaces to approximal surfaces has been demonstrated by epidemiological studies. Two recent meta-analyses evaluated the performance of visual examination and radiography for carious lesion detection, and reported low sensitivity but high specificity for early approximal caries detection. This suggests that the conventional methods have a higher risk o...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملCone Beam Ct in Occlusal Caries Research
Background: During the past few decades, changes have been observed not only in the prevalence of dental caries, but also in the distribution and pattern of the disease in the population. Most conventional radiographic imaging of teeth underestimates the presence of caries. Cone-beam CT is a new technology which can provide volumetric data of the object, from which cross-sectional images can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 29 1 شماره
صفحات -
تاریخ انتشار 2015