Investigation of a 90 Degree Spherical Deflecting Analyzer Operated in an Asymmetrically Charged Configuration
نویسندگان
چکیده
The electron optics of a 90 degree spherical deflecting analyzer (SDA-90) is investigated with an imaging matrix formalism. As a preanalyzer in the UTAneutrino experiment, high transmission and reasonable energy resolution are the choices of optimization. The magnification of the source through the analyzer plays the key role in determining the energy resolution. The imaging matrix approach provides graphical information to facilitate such an evaluation. We can demonstrate that in case where the analyzer is asymmetrically charged, the rotation of the image helps increase both transmission probability and resolution. A telefocus electron gun is used to check the numerical result, and to investigate the transverse focusing behavior.
منابع مشابه
Investigation of relationship with electron configuration of chemical hardness, absolute electronegativity and electrophilicity
Chemical hardness (), absolute electronegativity (), and electrophilicity () have importantapplications in inorganic chemistry. These concepts are defined quantitatively as � � �� � ����,� � �� � ����, � � ������Where I is the ionization energy and A is the electron affinity. In thisstudy, graphical method was used to see the relation of electron configuration with chemicalhardness, absolute el...
متن کاملAn Experimental Investigation of the Effects of Canard Position on the Aerodynamic Forces of a Fighter Type Configuration Model
An extensive experimental investigation is conducted to study the effect of canard position relative to the fuselage reference line on the aerodynamic forces of a fighter type configuration model. Aerodynamic forces at different flight conditions are measured in a subsonic wind tunnel. The wing and the canard have triquetrous shapes. Experiments are conducted at Reynolds number of 342209 and at...
متن کاملShielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملDetermination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملAn Investigation on the Effects of Charged Polyacrylamide Injection on Asphaltene Deposition in Porous Media
This study has been investigated, the effects of three different polar polyacrylamides (anionic, cationic, and nonionic) on asphaltene deposition in porous media. All experiments were carried out in various dead oil flow rates (0.2, 0.1 and 0.02 cc/min) and different polymer concentrations (500, 2500, 4000 ppm). The results indicated that asphaltene precipitation was affected by the presence of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999